Sizing sub-mains and final circuits, and reading maximum demand by AS/NZS 3000 Table C2.
- 3 min readShop and office maximum demand by floor areaEstimate the maximum demand of a small retail and office building from its floor area with AS/NZS 3000 Table C3, with basement EV charging and the range.

- 5 min readWorked examples index by tool and tradeEvery AmpSize worked example in one place, grouped by calculator and tagged with the trade it was written for, from house circuits to industrial boards.

- 3 min readIDMT grading main switch and submainTwo IEC standard inverse relays graded at an 8 kA fault on a commercial building, showing how an instantaneous setting overrides the curve and sets the margin.

- 3 min readMaximum demand block of flats with Table C1Eighteen living units on a three phase supply assessed with AS/NZS 3000 Table C1, group by group, giving the demand per phase for the network application.

- 3 min readTransformer kVA to amps 400 V for 750 kVAA 750 kVA 11 kV to 400 V transformer at 5 percent impedance, with primary and secondary full load current and the secondary fault current for the board spec.

- 4 min read63 A three‑phase submain buried in QueenslandA 63 A three-phase submain buried direct in hot Queensland ground, sized on AS/NZS 3008.1.1:2025 with the soil and depth factors, then run again on 2017.

- 4 min readCable size for a 32 A circuit, Australia 2025A 32 A single-phase circuit run 25 m at 40 °C, sized on AS/NZS 3008.1.1:2025 and checked against the 2017 edition, with the voltage drop and the next size up.

- 4 min readVoltage drop for AS3000 on a 2025 runA 32 A single-phase run of 40 m, checked for voltage drop with the mV/A·m values of AS/NZS 3008.1.1:2025 against the 5 % limit, in copper and aluminium.

- 3 min readkVA to amps 3 phase for a 75 kVA chillerA 75 kVA chiller nameplate converted to full load current at 400 V three phase, with the real power figure an estimator needs for a Table C2 demand line.

- 3 min readArc flash label calculation at 400 VIncident energy, arc flash boundary and PPE category for a 400 V commercial main switchboard at 12 kA with a 0.3 s clearing time and a 600 mm working distance.

- 3 min readSupply application kVA from maximum demandNetwork connection kVA from a maximum demand of 250 A at 400 V, with the real power in kW and the reactive power in kvar for the application form.

- 3 min readAS/NZS 3000 Cl 7.9: EV charging in NZWhat Clause 7.9 of AS/NZS 3000 governs for EV charging circuits, which tools read it, and a 32 A garage charger that lands on 10 mm² over 25 m.

- 3 min readVoltage rise for a 10 kW three‑phase inverterVoltage rise for a 10 kW three-phase inverter on 50 m of 6 mm² cable, with the inverter current, the rise in volts and percent, and the maximum length.

- 3 min readConduit size for 35 mm cable in a submainFour 35 mm² singles in a 50 mm conduit fill 19.48 % of the internal area, and the AmpSize engine still recommends a 40 mm conduit for this submain.

- 5 min readBuilder's pole: supply, RCDs and cord lengthsA builder's pole for a house build, worked to AS/NZS 3012:2019. The supply it may take, the 30 mA RCDs, the Table 1 cord lengths and the test intervals.

- 4 min readCar-park floodlight: obtrusive light at a boundaryTwo 10 000 lm floodlights 10 m from a neighbour's window in zone A2, checked against AS/NZS 4282 for lux at the window, candela and the upward light ratio.

- 3 min readCommercial kitchen kW to amps full load currentTurning a 30 kW commercial kitchen nameplate load into 45.58 A at 400 V three phase, with the power factor step that a plain kW to amps sum leaves out.

- 3 min readLighting circuit loop impedance, B curve 10 AA 60 m shop lighting circuit on 1.5 mm² cable with a B curve 10 A device, showing Zs, the maximum Zs, the fault current and the longest run that passes.

- 5 min readCable tray fill for a plant room: a second tierLay ten multicore cables on a 300 mm perforated tray in one layer, see when it takes a second tier, and carry the grouping factor into the cable size.

- 4 min readSwitchboard fault rating at 25 kA for 1 sA 1 second withstand check at 25 kA on 185 mm² copper XLPE, returning a 174.83 mm² minimum size and a 26.46 kA withstand, with a thin margin explained.

- 3 min readGenerator full load current: 200 kVA to ampsA 200 kVA 400 V standby set converted to 288.68 A of full load current, 160 kW of real power and 2,405.63 A of initial fault current from 12 percent reactance.

- 3 min readOffice maximum demand per phase with Table C2An office fitout load schedule assessed against AS/NZS 3000 Table C2, group by group, landing on 413.7 A across three phases and 137.9 A per phase.

- 1 min readHow far can 4 mm² run on a 25 A circuit?4 mm² copper on a 25 A curve C circuit can run 41 m at full load before it reaches the 5 % voltage drop limit. At 20 A of load it can run 51.25 m.

- 1 min readHow many amps can 10 mm² cable carry?10 mm² copper multicore PVC cable carries 50 A enclosed in air at 30 °C in NZ, so a 50 A breaker protects it. Clipped direct, it carries 58 A.

- 1 min readHow many amps can 16 mm² cable carry?16 mm² copper multicore PVC cable carries 66 A enclosed in air at 30 °C in NZ, so it takes a 63 A breaker. Grouped with two circuits, it carries 46.2 A.

- 1 min readHow many amps can 6 mm² cable carry?6 mm² copper multicore PVC cable carries 38 A enclosed in air at 30 °C in NZ, so it takes a 32 A breaker. At 40 °C it carries 33.44 A.

- 1 min readHow many 2.5 mm² cables fit in 20 mm conduit?Six single-core 2.5 mm² cables fit in 20 mm conduit at 34.56 % fill, inside the 40 % limit of AS/NZS 3000 Appendix C. A seventh takes it to 40.32 %.

- 1 min readMaximum Zs for a 16 A curve C breakerAS/NZS 3000 Table 8.1 allows a maximum Zs of 1.92 Ω for a 16 A curve C breaker at 230 V. A 30 m run of 2.5 mm² cable reads 0.89 Ω.

- 1 min readVoltage drop on 2.5 mm² over 30 m20 A on 2.5 mm² copper over 30 m drops 10.81 V, which is 4.7 % at 230 V and close to the 5 % limit. The run can reach 31.91 m.

- 1 min readWhat size cable for a 22 kW EV charger?A 22 kW three-phase EV charger on a 32 A circuit takes 6 mm² copper over 20 m, with 38 A of derated capacity and a 1.04 % drop. At 60 m it takes 10 mm².

- 1 min readWhat size cable for a 25 A circuit?A 25 A single-phase circuit takes 4 mm² copper on a typical NZ route, with 29 A of derated capacity. 2.5 mm² stops at 23 A, short of the breaker.

- 3 min readSubmain voltage drop estimate for a 160 A tenderA price stage check on a 160 A submain over 80 m on 70 mm² XLPE. See the mV/A·m figure, the 1.89 percent drop and the length the budget allows.

- 3 min readSubmain cable size for 3‑phase 100 A over 60 mA 100 A tenancy submain on tray over 60 m at 40 °C. See the derating chain, the four checks and why the loop impedance check sets the size at 70 mm².

- 3 min readThree‑phase power: kVA to amps at 400 VThe root three relation between amps, kVA and kW on a 400 V board, worked at 50 A and a 0.9 power factor, with the kvar figure the engine returns.

- 3 min readFactory power factor correction: 250 kW at 0.78A 250 kW factory load at 0.78 power factor lifted to 0.95. The kvar, the capacitor steps, the current saved, the kVA released and why the bank is detuned.

- 3 min readFault level at a sub‑board, 300 kVA transformerWork the prospective fault current at a sub-board 45 m from a 300 kVA transformer, three-phase and phase-earth, and check 6 kA and 10 kA breakers against it.

- 5 min readThree circuits in a hot ceiling: correction factorThree 32 A circuits in conduit across a 40 °C and a 50 °C ceiling space, worked with the NZ 2017 tables and again with AS/NZS 3008.1.1:2025.

- 5 min readWhat size breaker for 4 mm² cable4 mm² copper enclosed in air takes a 25 A breaker, and 32 A fails at an Iz of 29 A. Grouping, a hot ceiling, insulation and a long run lower it.

- 3 min read22 kW EV charger amps at 400 V three‑phaseA 22 kW three-phase EV charger draws 31.75 A at 400 V. See the inputs, the clause, the arithmetic and the current that feeds cable sizing and demand.

- 3 min readGenerator sizing for a 150 kVA holiday parkA 150 kVA three-phase standby set at 400 V gives 216.51 A full load current, 120 kW real power and 1443.38 A fault current from one nameplate.

- 4 min readElectrical estimating calculators NZ roundupA roundup of the calculators a New Zealand estimator uses at price stage, with a Table C2 fitout worked through to a demand of 102.95 A per phase.

- 4 min readCable size for a 20 A heat pump circuit in summerA 20 A heat pump circuit over 18 m in a 40 °C roof space needs 4 mm², with a derated capacity of 22.88 A and a voltage drop of 1.59 percent.

- 4 min readAmpSize vs jCalc vs free cable sizing toolsCompare AmpSize with jCalc and other free cable sizing tools. One 63 A three-phase submain shows which checks decide a size, and what AmpSize leaves out.

- 4 min readAS/NZS 3000 Appendix C: conduit space factorWhat the conduit space factor in AS/NZS 3000 Appendix C governs, which tool reads it, and a worked 50 mm conduit that reaches 52.95 % fill against a 40 % limit.

- 4 min readAS/NZS 3008.1.2 Table 52: the k factorWhat Table 52 governs, how the adiabatic check uses k, and a 10 kA fault cleared in 0.1 s that needs 22.11 mm² against an installed 25 mm² conductor.

- 3 min readAS/NZS 3000 Tables C1 and C2: demand groupsWhat the demand group letters govern, when to use Table C1 or Table C2, and a commercial assessment that returns 276.26 A total and 92.09 A per phase.

- 4 min readAS/NZS 3008.1.2 Tables 22 to 29: deratingWhat the derating tables govern, how ambient and grouping combine into one factor, and a 63 A feeder whose capacity falls to 78.85 A on 35 mm² copper.

- 6 min readAS/NZS 3008.1.1 table numbers: 2017 to 2025Each AS/NZS 3008.1.1 table AmpSize reads, with its 2017 number, its 2025 number and whether its values moved, and one submain that cites both sets.

- 4 min readAS/NZS 3008.1.1 vs 3008.1.2: AU and NZ conditionsThe AU part of AS/NZS 3008.1 rates cable at 40 °C air and the NZ part at 30 °C. One 32 A circuit needs 6 mm² in Australia and 4 mm² in New Zealand.

- 4 min readAS/NZS 3008.1.2 Tables 4 to 21: current ratingsWhat the current rating tables govern, which table AmpSize reads today, and a 40 A circuit that lands on 10 mm² with a derated capacity of 50 A.

- 4 min readAS/NZS 3008 Table 13 (now 3.18): multicore ratingsWhat AS/NZS 3008 Table 13 gives, why the 2025 AU part calls it Table 3.18, how to read its columns into the calculator, and what moved for buried cable.

- 3 min readAS/NZS 3008 Table 22 (now 3.33): bunched groupingAS/NZS 3008 Table 22 is the grouping table for bunched circuits, not a temperature table. The 2025 AU part calls it Table 3.33. Read it in the calculator.

- 3 min readAS/NZS 3008 Table 27 (now 3.44, 3.45): temperatureAS/NZS 3008 Table 27 corrects a cable rating for the air or soil temperature. The 2025 AU part splits it into Tables 3.44 and 3.45 and re-derives the factors.

- 5 min readAS/NZS 3008 vs BS 7671: cable sizing comparedHow BS 7671 and AS/NZS 3000 with AS/NZS 3008.1 size a cable, where they differ, and why a BS current rating never converts into an AS/NZS one.

- 4 min readAWG and the NEC for NZ and AU electriciansAWG sizes and the NEC set against AS/NZS 3000 and 3008.1. A gauge converts to mm², but its rating does not, and the NEC 3 % drop figure is only a note.

- 3 min readConduit fill: 4 x 6 mm² singles in 25 mmFour 6 mm² single-core cables in 25 mm conduit, with the fill percent, the space factor and the smallest conduit the tool recommends for the bundle.

- 3 min readCommercial maximum demand with Table C2A tender-stage demand assessment for a commercial building using AS/NZS 3000 Table C2, with each group demand and the per-phase figure the tool returns.

- 3 min readProspective fault current at a main switchboardA 16 kA fault cleared in 0.1 s on 70 mm² copper XLPE, with the minimum conductor size, the withstand current and the k factor the adiabatic check returns.

- 3 min readAS/NZS 3000 Table 8.1: max Zs by curve and ratingTable 8.1 max Zs for a 16 A device, by curve. B allows 3.59 Ω, C allows 1.92 Ω and D allows 1.15 Ω. See why, with a 30 m circuit at 0.89 Ω.

- 5 min readAS/NZS 3008.1.1:2025: what changed from 2017The 2025 AU part adds d.c. ratings to 1500 V, renumbers every table and moves some ratings. Four circuits, each run on both editions, show what moves.

- 3 min readAS/NZS 3000 Clause 3.6.2: voltage drop limitWhat Clause 3.6.2 governs, how the 5 percent budget splits across mains and subcircuits, and a 25 A run over 35 m that returns 2.6 percent from the engine.

- 4 min readCable size for a 32 A single‑phase 25 m runWork through a 32 A single-phase circuit over 25 metres in New Zealand. See every derating factor, the check that sets the size, and the result the tool gives.

- 4 min readEarth fault loop impedance and maximum ZsWhat earth fault loop impedance measures, how the maximum Zs check works, and a 32 A circuit on 6 mm² over 25 m that lands on 0.67 ohms against a 0.96 limit.

- 3 min readVoltage drop with the mV/A·m methodHow the millivolt per amp metre method works, with a 32 A run over 25 metres on 6 mm² copper and the exact drop, percent and maximum length the tool returns.

Calculators these guides use
- Floor area demand calculatorEstimate commercial demand from floor area and use.
- Cable size calculatorFind the smallest cable size that passes each check.
- IDMT grading calculatorPlot the trip curves of inverse-time overcurrent relays.
- Maximum demand calculatorEstimate maximum demand for domestic or non‑domestic loads.
- Transformer calculatorCalculate transformer full load current and impedance.
- Voltage drop calculatorCalculate voltage drop on a cable run and check the limit.
- Full load current calculatorCalculate full load current from power, voltage and phase.
- Arc flash calculatorEstimate the energy of an arc flash and its PPE category.
- Three phase power calculatorConvert between power, current, voltage and power factor.
- Voltage rise calculatorCalculate voltage rise for embedded generation or PV.
- Conduit fill calculatorCheck that a cable bundle fits in a conduit.
- Site cord length calculatorThe longest a cord or cable may run on a construction site.
- Obtrusive light checkerCheck outdoor light at a boundary window by AS/NZS 4282.
- Earth fault loop impedance calculatorCheck earth fault loop impedance against the maximum Zs.
- Cable tray and ladder fillTray or ladder width, tiers, kg/m and the grouping factor.
- Cable fault rating calculatorCheck that a conductor can withstand the fault current.
- Generator current calculatorFull load and fault current of a generator from its kVA.
- Maximum circuit length calculatorLongest run that voltage drop and the fault loop allow.
- Existing circuit checkCheck an installed circuit: cable, device, drop and Zs.
- Power factor correction calculatorFind the capacitor kvar to lift a power factor.
- Fault level calculatorProspective fault current at a board from its source.
- Correction factor calculatorRead each correction factor and the rating a cable needs.
- Imperial cable size converterFind the device rating for an old imperial cable.