Foundation level
The ideas a reader needs before the first calculation: current, volt drop and the MEN system.
- 4 min readCable size for an estimate: length mattersHow run length moves a cable size from 10 mm² to 25 mm² at the same current, worked at 30 m, 60 m, 120 m and 200 m, and what an estimator should record.

- 4 min readConduit fill and installation methodsHow the conduit space factor works, what the fill percent means against the 40 percent limit, and how the install method names on site map to the 3008 columns.

- 5 min readCurrent-carrying capacity and deratingWhy one cable size has many ratings. Install method, ambient, grouping, soil and depth, with a 25 A circuit that needs 10 mm² once the factors apply.

- 3 min readDownlights and insulation: IC-4, CA90 and Non‑ICThe six recessed luminaire classes, what insulation may do around each, which a NZ or AU home may have, the default clearances, and the roof space warning sign.

- 3 min readHome batteries and AS/NZS 5139How a home solar battery is sized in kWh, what usable, nominal, depth of discharge and round-trip efficiency mean, and where AS/NZS 5139 lets one go.

- 4 min readHome battery location and clearancesWhere AS/NZS 5139 lets an all-in-one home battery go. Restricted places, 600 and 900 mm zones, the habitable room barrier, ceiling, IP codes and working space.

- 3 min readHow AmpSize sizes a cable: load to certificateThe route from a load to a certified circuit in seven steps. Each step names the tool, the learn page and the guides, with one 32 A circuit worked through.

- 3 min readHow many circuits can go on one RCDThe AS/NZS 3000 Cl 2.6.2.4 arrangement rules in plain words, which circuits need a 30 mA RCD in NZ and AU homes, how RCBOs count, and why the rules exist.

- 3 min readIP ratings explained: each digit and letterWhat the two numerals of an IP code mean, what X, the letters A to D and H, M, S, W add, why IP67 is not better than IP65 for jets, and where 3000 sets a code.

- 4 min readMEN system: multiple earthed neutral explainedMEN means multiple earthed neutral. In NZ, earth and neutral join at the main switchboard. A fault on a 32 A C curve circuit then draws 343.8 A and clears.

- 6 min readOhm's law and power on d.c. and a.c.Ohm's law and the power formulas on d.c., single-phase and three-phase a.c.: how power factor and impedance change them, and how any two values give the rest.

- 3 min readPower points near a cooktop, gas bottle and sinkThe AS/NZS 3000 zones that keep power points, switches and lights away from cooktops, gas cylinders, gas vents and regulators, and where sinks are checked.

- 2 min readSwitchboard labels and circuit chartsWhat AS/NZS 3000 asks a switchboard to carry: a chart tying each device to what it supplies, MAIN SWITCH, MAIN SWITCHBOARD, solar labels and marked neutrals.

- 3 min readThe 5 % voltage drop limit from supply to loadWhat AS/NZS 3000 Cl 3.6.2 limits, how the drop of the mains, submains and final subcircuits adds by percent, the four exceptions and why any split is yours.

- 2 min readThe order of verification testsWhy AS/NZS 3017 tests earth continuity before insulation and loop impedance before RCDs, which circuits take which test, and where each limit comes from.

- 4 min readVoltage drop basicsOhm's law on a cable, the mV/A·m shortcut, the percent limit and the maximum length, worked on a 25 A run over 35 m of 4 mm² copper.

- 4 min readWho may do electrical work in NZThe regulations that govern prescribed electrical work and its certification in New Zealand, named by number, with the paperwork abbreviations explained.

- 2 min readWire colours in NZ and Australia, old and newThe active, neutral and earth colours of AS/NZS 3000 Table 3.4, the NZ black neutral, older yellow and green conductors, and flexible cord colours.

Calculators these guides use
- Cable size calculatorFind the smallest cable size that passes each check.
- Voltage drop calculatorCalculate voltage drop on a cable run and check the limit.
- Maximum demand calculatorEstimate maximum demand for domestic or non‑domestic loads.
- Conduit fill calculatorCheck that a cable bundle fits in a conduit.
- Downlight clearance checkIC, CA90 or Non‑IC: may insulation touch the light?
- Correction factor calculatorRead each correction factor and the rating a cable needs.
- Solar battery calculatorSize a home battery for the solar evening load.
- Battery bank calculatorCalculate battery bank capacity and autonomy for a load.
- DC cable size calculatorSize a d.c. cable up to 1500 V for current and voltage drop.
- Battery location checkerCheck where a home battery can go under AS/NZS 5139.
- Earth fault loop impedance calculatorCheck earth fault loop impedance against the maximum Zs.
- Cable fault rating calculatorCheck that a conductor can withstand the fault current.
- Test results checkerCheck measured test results against Section 8 limits.
- RCD arrangement checkCheck circuits per RCD and the lighting split.
- RCD selection calculatorCheck if an RCD is required and test the trip time.
- IP rating chart and decoderDecode an IP code and find the least for a location.
- Wet area zones checkerFind the Section 6 zone, IP and RCD near water.
- Ohm's law and powerAny two of V, I, R and P give the other two.
- Three phase power calculatorConvert between power, current, voltage and power factor.
- Full load current calculatorCalculate full load current from power, voltage and phase.
- Power point location checkPower points near a cooktop, gas cylinder, vent or sink.
- Switchboard circuit chartMake a board circuit chart and the labels it needs.
- Switchboard form checkerCheck separation, access and clearances for a switchboard.
- Total voltage drop calculatorAdd the drop of mains, submain and final against 5 %.
- Test schedule for a switchboardPrint a board test sheet with the limit for each test.
- Voltage rise calculatorCalculate voltage rise for embedded generation or PV.
- Electrical certification pathwayFind the paperwork for a job in NZ or Australia.
- Electrical wire colour guideFind wire colours for fixed wiring and cords, old and new.
- Test and tag intervalsRetest intervals and pass limits for portable gear.