NZS 4512:2010

The New Zealand standard for fire alarm and detection systems. AmpSize uses it for the sound pressure level an audible alerting device must reach. AmpSize reads that level for a room, a bedhead and a balcony. It also reads the ambient level that calls for a visual alerting device.

Notes

Edition cited
NZS 4512:2010
Amendments applied
  • No amendment named in the source (5 tables)
Tables last checked
26 Sept 2026
Tables
5: 5 verified
Clauses
15

No text of the standard is reproduced here. AmpSize is a design aid. Verify results against the current standard.

Contents (20)

Clauses (15)

Tables (5)

  • Fire alarm standby battery periods, cell voltages and test criterion

    The fire alarm battery tool reads the two standby periods, the alarm period, the recharge period, the float voltage and its tolerance, the current limit voltage, the nominal cell voltage, the service life and the three monthly test figures, from Clauses 211.5, 212, 213 and 602.7. The periods are minimum periods, so the tool holds a minimum capacity before the factors and never reports less than that figure.

    Verified: read against the printed standard, pages 28–30, 73. Checked 26 Sept 2026.

    See the values

    Tools that read it:

    Fire alarm battery calculator.

  • Cl 402

    Fire alarm cable and circuit requirements

    The fire alarm cabling tool reads one row per circuit type. Each row holds the smallest conductor size for two cores and for more than two, and the stranding threshold. It also holds the insulation resistance criterion, the AS/NZS 3013 fire rating and integrity time, and the supply subcircuit label. A null size means Clause 402.1 sets none for that circuit.

    Verified: read against the printed standard, pages 44–45. Checked 26 Sept 2026.

    See the values

    Tools that read it:

    Fire alarm cabling lookup.

  • Detector spacing, wall distance and coverage

    The detector spacing tool reads one row per detector type. Each row holds the spacing, the corridor spacing, the wall distance and the corridor wall distance. It holds the floor area per detector and the longest distance from any point to a detector, line or beam. Last is the limit below the apex of a sloping roof. A null wall distance means Clause 405.3 states none for that type.

    Verified: read against the printed standard, pages 43, 52–53, 59–60. Checked 26 Sept 2026.

    See the values

  • Cl 406

    Alerting device sound pressure levels

    The sounder level tool reads the 10 dB and 5 dB margins over the residual level, the 65 dB to 100 dB band, the bedhead and balcony levels, the 90 dB visual device trigger, the care area margin and the measurement height, from Clauses 406.3, 406.4 and 406.7.

    Verified: read against the printed standard, pages 62–63. Checked 26 Sept 2026.

    See the values

  • Fire alarm monthly and annual check intervals

    The assessment interval tool reads the monthly and annual check cadence from Clauses 602 and 603. Two rows only, each carrying its interval in months and its clause number.

    Verified: read against the printed standard, pages 73–76. Checked 26 Sept 2026.

    See the values

    Tools that read it:

    Periodic assessment intervals.

Guides and learn pages that cite it (1)

All 24 documents