AS/NZS 3017:2022
The guide to verifying an installation by inspection and testing. The test results tool cites it beside AS/NZS 3000 Section 8 where its figures match. Its loop impedance table is rounded, so Section 8 stays the reference for Zs. The test schedule tool reads its sequence of tests, and its RCD result for an Australian sheet.
Notes
- Edition cited
- AS/NZS 3017:2022
- Amendments applied
- No amendment named in the source (1 table)
- Tables last checked
- 1 Oct 2026
- Tables
- 1: 1 verified
- Clauses
- 11
No text of the standard is reproduced here. AmpSize is a design aid. Verify results against the current standard.
Contents (12)
Clauses (11)
Order of tests
The test schedule tool puts the tests in the order this clause sets. It adds a last step: repeat a failed test and the tests it may have upset.
Tools that read it:
Test for de-energized
The test schedule tool lists this test first in the sequence, from this clause.
Tools that read it:
Earth continuity test method
The test schedule tool lists the earth continuity test in the sequence and cites this clause for its method.
Tools that read it:
Earth continuity results
The test results tool cites this clause beside Section 8 for the 0.5 ohm limit of the main earthing and bonding conductors. Both give the same figure.
Tools that read it:
Insulation resistance test method
The test schedule tool lists the insulation resistance test in the sequence and cites this clause for its method.
Tools that read it:
Insulation resistance results
The test results tool cites this clause beside Section 8 for the least insulation resistance. The figures match for each circuit kind the tool offers.
Tools that read it:
Polarity and circuit connections test method
The test schedule tool lists the polarity and circuit connections test. It cites this clause for the method.
Tools that read it:
Polarity and circuit connection results
The test results tool points to this clause for what a polarity and connection test must show.
Tools that read it:
Phase sequence test method
The test schedule tool lists the phase sequence test for multi-phase socket-outlets and cites this clause for its method.
Tools that read it:
Earth fault-loop impedance test method
The test schedule tool lists the earth fault-loop impedance test in the sequence and cites this clause for its method.
Tools that read it:
RCD operation test method
The test schedule tool lists the RCD operation test in the sequence and cites this clause for its method.
Tools that read it:
Tables (1)
The sequence of verification tests and what each covers
The test schedule tool reads the order of the verification tests and which circuits each reaches: the phase sequence test for multi-phase socket-outlets, the RCD test where a circuit has one.
Verified: read against the printed standard, pages 13-14, 41-42, 55-56 (PDF 21-22, 49-50, 63-64). Checked 1 Oct 2026.