Table 4.1

Voltage correction factors for crystalline silicon PV modules

The PV string tool reads the voltage correction factor for the record low when you pick the table method. Verified on printed page 29.

Verified: read against the printed standard, pages 29 (PDF 37). Checked 1 Oct 2026.

Units: From C °C, To C °C, Factor x

These are the values AmpSize encodes. No text of the standard is reproduced. Verify against the current standard.

Back to its card on the AS/NZS 5033:2021 page

13 rows

Table 4.1, Voltage correction factors for crystalline silicon PV modules
From C (°C)To C (°C)Factor (x)
24201.02
19151.04
14101.06
951.08
401.1
−1−51.12
−6−101.14
−11−151.16
−16−201.18
−21−251.2
−26−301.21
−31−351.23
−36−401.25