Table 4.1

Voltage correction factors for crystalline silicon PV modules

The PV string tool reads the voltage correction factor for the record low when you pick the table method. Verified on printed page 29.

Kua manatokotia: pānuitia ki te paerewa tā, whārangi 29 (PDF 37). I tirohia 1 Oct 2026.

Ngā unit: From C °C, To C °C, Factor x

Ko ēnei ngā uara e tuhia ana e AmpSize. Kāore he kupu o te paerewa e tuhia ana. Whakamanahia ki te paerewa o nāianei.

Hoki ki tana kāri i te whārangi AS/NZS 5033:2021

13 rārangi

Table 4.1, Voltage correction factors for crystalline silicon PV modules
From C (°C)To C (°C)Factor (x)
24201.02
19151.04
14101.06
951.08
401.1
−1−51.12
−6−101.14
−11−151.16
−16−201.18
−21−251.2
−26−301.21
−31−351.23
−36−401.25