Table 3.2

Light technical parameter limits

The obtrusive light tool reads the vertical illuminance limit at a window, curfew or not, and the upward light ratio limit for the installation. It does not use the threshold increment.

Verified: read against the printed standard, pages 25. Checked 1 Oct 2026.

Units: Ev non curfew lx lx, Ev curfew lx lx, Ti max percent %, Lad cd M 2 cd/m², Ulr max ratio

These are the values AmpSize encodes. No text of the standard is reproduced. Verify against the current standard.

Back to its card on the AS/NZS 4282:2023 page

6 rows

Table 3.2, Light technical parameter limits
ZoneEv non curfew lxEv curfew lxTi max percent (%)Lad cd M 2 (cd/m²)Ulr max (ratio)Near zeroLad sign note
A000——0yesno
A120.1200.10nono
A251200.20.01noyes
A31022010.02nono
A42552050.03nono
TV——20100.08nono