跳至内容
AmpSize

This page is not in 简体中文 yet, so you are reading the English.

· 阅读约 5 分钟

Worked examples index by tool and trade

电缆截面计算器

+4 references

Worked to AS/NZS 3000:2018 and AS/NZS 3008.1.2:2017 (NZ). Tables checked 27 Sept 2026.

The inside of an electrician's van, with cable reels, tool cases and test gear on shelves.

Every guide on this site is one calculation, run end to end, with the table behind each number. The index below groups them by calculator and tags each one with the trade it was written for.

The shape of a worked example

Take the shortest case on the site. A single‑phase circuit carries 20 A at 230 V over 15 m. The cable is multicore copper with PVC insulation, enclosed in air at 30 °C. One circuit shares the route. The device is a 20 A C curve and Ze is 0.35 Ω.

Selection follows AS/NZS 3000:2018 Cl 3.4, with ratings from AS/NZS 3008.1.2:2017 Tables 4-21. The total derating factor is 1, so the required tabulated current stays at 20 A. The answer is 2.5 mm². The derated capacity is 23 A and the drop is 2.13 %. Zs is 0.62 Ω on a 2.5 mm² earth conductor.

Every guide below follows that order: the circuit, the clause, the steps, the result.

Index by calculator

Arc flash

Battery

Cable size

Conduit fill

Fault rating

Full load current

Generator

IDMT protection

Loop impedance

Maximum demand

Motor

Three‑phase power

Transformer

Voltage drop

Voltage rise

The tag after each link names the trade the example was written for. The method still applies across trades: a 400 V motor feeder and a 230 V heat pump circuit take the same five checks.

To compare AmpSize with other cable size calculators, read the cable size calculators compared table.

This page is a design aid. Verify every value against the current edition of the standard.

See also: Current-carrying capacity and derating, Maximum demand and diversity and IB ≤ IN ≤ IZ: the overload rule on a 32 A circuit.

使用这些输入试用

环境温度
30 °C
芯线
多芯
装置曲线
C 型曲线
检查保护装置
是
成组回路
1
绝缘
PVC 75 °C
敷设长度
15 m
设计电流
20 A
材料
铜
敷设方式
Enclosed in air
功率因数
0.9
相
单相
保护装置额定值
20 A
电压降限值
5 %
电压
230 V
外部阻抗 Ze
0.35 Ω
使用这些输入打开计算器

下一步

其背后的概念

更多示例

AmpSize 是设计辅助工具。请对照现行标准核实结果。

这是否有用?

有问题,或数值看起来有误?联系我们。