AS/NZS 3000:2018
Table C8
Simplified voltage drop, ampere metres per percent
The simplified selector reads the ampere metres per percent of voltage drop that Table C8 gives. It reads them for each conductor size, for one phase and for three. The table stops at 95 mm², and the tool says so rather than extrapolating.
已核验:对照印刷版标准阅读,页码 481。检查于 26 Sept 2026。
单位:Size mm2, Am per percent A*m per %
这些是 AmpSize 所编码的数值。不转载标准原文。请依据现行标准核对。
12 行
| Size (mm2) | Single phase | Three phase |
|---|---|---|
| 1 | 45 | 90 |
| 1.5 | 70 | 140 |
| 2.5 | 128 | 256 |
| 4 | 205 | 412 |
| 6 | 306 | 615 |
| 10 | 515 | 1034 |
| 16 | 818 | 1643 |
| 25 | 1289 | 2588 |
| 35 | 1773 | 3560 |
| 50 | 2377 | 4772 |
| 70 | 3342 | 6712 |
| 95 | 4445 | 8927 |