AS/NZS 1680.1:2006
Table 3.1
Recommended maintained illuminances for various types of tasks, activities or interiors
The lighting lumen method tool reads the maintained illuminance for a class of task. It maps each workplace room use to one class, and names the table in its steps. The rows are workplace interiors. A house’s rooms, its kitchen and garage too, and outside areas are not in this table, so the tool marks their targets as typical.
已核验:对照印刷版标准阅读,页码 19 (PDF 21)。检查于 1 Oct 2026。
单位:Lux lx
这些是 AmpSize 所编码的数值。不转载标准原文。请依据现行标准核对。
10 行
| Label | Lux (lx) | Interiors |
|---|---|---|
| Movement and orientation | 40 | corridors, walkways |
| Rough intermittent | 80 | live storage of bulky materials, loading bays |
| Simple | 160 | entrance halls, automated process monitoring |
| Ordinary or moderately easy | 240 | food preparation, counters for transactions |
| Moderately difficult | 320 | routine office tasks |
| Moderately difficult | 400 | inspection of medium work |
| Difficult | 600 | drawing boards, proofreading |
| Very difficult | 800 | fine inspection |
| Extremely difficult | 1200 | graphic arts inspection |
| Exceptionally difficult | 1600 | watchmaking |