Whakawhiti ki te ihirangi
AmpSize

AS/NZS 1680.1:2006

Table 3.1

Recommended maintained illuminances for various types of tasks, activities or interiors

The lighting lumen method tool reads the maintained illuminance for a class of task. It maps each workplace room use to one class, and names the table in its steps. The rows are workplace interiors. A house’s rooms, its kitchen and garage too, and outside areas are not in this table, so the tool marks their targets as typical.

Kua manatokotia: pānuitia ki te paerewa tā, whārangi 19 (PDF 21). I tirohia 1 Oct 2026.

Ngā unit: Lux lx

Ko ēnei ngā uara e tuhia ana e AmpSize. Kāore he kupu o te paerewa e tuhia ana. Whakamanahia ki te paerewa o nāianei.

Hoki ki tana kāri i te whārangi AS/NZS 1680.1:2006

10 rārangi

Table 3.1, Recommended maintained illuminances for various types of tasks, activities or interiors
LabelLux (lx)Interiors
Movement and orientation40corridors, walkways
Rough intermittent80live storage of bulky materials, loading bays
Simple160entrance halls, automated process monitoring
Ordinary or moderately easy240food preparation, counters for transactions
Moderately difficult320routine office tasks
Moderately difficult400inspection of medium work
Difficult600drawing boards, proofreading
Very difficult800fine inspection
Extremely difficult1200graphic arts inspection
Exceptionally difficult1600watchmaking

Ngā taputapu e pānui ana i tērā (1)