跳至内容
AmpSize

This page is not in 简体中文 yet, so you are reading the English.

· 阅读约 1 分钟

How many amps can 2.5 mm² carry in Australia?

现有回路检查

+2 references

Worked to AS/NZS 3008.1.1:2025 (AU) and AS/NZS 3000:2018. Tables checked 27 Sept 2026.

修正后载流量 Iz

20A

电缆允许的最大 C 曲线装置
20A
电压降
3.13%
装置的最大 Zs
1.53Ω
使用这些输入打开计算器

此结果仅供设计参考。请对照现行标准进行核验。

A drawn result card from the Circuit Check tool: circuit on 2.5 mm² passes.

2.5 mm² copper multicore PVC cable carries 20 A enclosed in air in Australia. The tool reads AS/NZS 3008.1.1:2025 Table 3.18 at its 40 °C air reference, with no derating. The largest curve C breaker it allows is 20 A, with no margin to spare.

The case

The circuit is single‑phase at 230 V and runs 20 m at the full 20 A of the breaker. The voltage drop is 3.13 % and the earth fault loop impedance is 0.71 Ω, inside the 1.53 Ω that Table 8.1 allows.

The circuit check reads Passes.

What changes the rating

Clipped direct to a surface, the cable carries 22 A.

The enclosed rating equals the breaker, so any derating fails a 20 A circuit on enclosed 2.5 mm². A grouped or insulated run needs the next size, or a smaller breaker.

See also: What size cable for power points in Australia? and AS/NZS 3008.1.1:2025 overview.

使用这些输入试用

环境温度
40 °C
芯线
多芯
装置曲线
C 型曲线
版本
AS/NZS 3008.1.1:2025
成组回路
1
绝缘
PVC 75 °C
标准
AU · AS/NZS 3008.1.1
敷设长度
20 m
设计电流
20 A
材料
铜
敷设方式
Enclosed in air
功率因数
1
相
单相
保护装置额定值
20 A
已安装电缆规格
2.5 mm²
电压
230 V
外部阻抗 Ze
0.35 Ω
使用这些输入打开计算器

下一步

其背后的概念

更多示例

AmpSize 是设计辅助工具。请对照现行标准核实结果。

这是否有用?

有问题,或数值看起来有误?联系我们。