Whakawhiti ki te ihirangi
AmpSize

Arotake Obtrusive Light

Tirohia te rama o waho i tētahi matapihi rohe e ai ki AS/NZS 4282.

Reads AS/NZS 4282:2023. Tables checked 1 Oct 2026.

Ngā whakauru

He tauira mahi me ngā whakauru taunoa.

Te rohe taiao
A2, Low district brightness
I te wā kati pō
Kāo
Tawhiti ki te rohe
10 m
Teitei o te pūtahi matapihi
1.5 m
Ngā whakarāmaha
1 rārangi

Te rama poutū i te matapihi

47.67lx

Te rohe o te rama poutū
5lx
Te kaha nui rawa ki te matapihi
3,143cd
Te rohe kaha ia rama
7,500cd
Te ōwehenga o te māramatanga ki runga
0.020
Te rohe o te ōwehenga o te māramatanga ki runga
0.01

He āwhina hoahoa tēnei hua. Manatokohia ki te paerewa o nāianei.

Ngā hīkoi tātaitanga

  1. Rohe taiaoA2, Low district brightness

    AS/NZS 4282:2023 Table 3.1

  2. WāI waho o te wā aukati

    AS/NZS 4282:2023 Cl 3.2.4

  3. Tauwhiwhi tiaki1

    AS/NZS 4282:2023 Cl 3.2.2

  4. Pūtahi matapihi10 m out, 1.5 m up

    AS/NZS 4282:2023 Cl 3.3.1.3

  5. Kaha teitei I04,775cd
  6. Koki i tawhio atu i te aho35.8°
  7. Kaha ki te matapihi3,143cd

    AS/NZS 4282:2023 Cl 3.3.1.3

  8. Ev i te matapihi, 2 × 23.836 lx47.67lx

    AS/NZS 4282:2023 Cl 3.3.1.3

  9. Te rama poutū i te matapihiHua47.67lx

    AS/NZS 4282:2023 Cl 3.3.1.3

  10. Te rohe o te rama poutū5lx

    AS/NZS 4282:2023 Table 3.2

  11. Te kaha nui rawa ki te matapihi3,143cd

    AS/NZS 4282:2023 Cl 3.3.1.3

  12. Te rohe kaha ia rama, Taumata 17,500cd

    AS/NZS 4282:2023 Table 3.3

  13. Lumen i runga ake i te pae400lm

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  14. Lumen katoa20,000lm

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  15. Te ōwehenga o te māramatanga ki runga0.02

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  16. Te rohe o te ōwehenga o te māramatanga ki runga0.01

    AS/NZS 4282:2023 Table 3.2

Mō tēnei tātaitai

How this is calculated

The tool estimates the light a floodlight or bollard puts on a neighbour window. It checks the result against AS/NZS 4282:2023.

  1. Zone and period. You pick the environmental zone, A0 to A4, and whether the curfew applies. Table 3.1 defines the zones. Cl 3.2.4 sets the curfew period.
  2. Intensity toward the window. The tool takes the beam angle and the tilt of each luminaire. It finds the angle off the beam axis. It then reads the intensity at that angle from a simple lobe (Cl 3.3.1.3).
  3. Vertical illuminance. For each luminaire, it divides the intensity by the squared distance to the window. It applies the maintenance factor of Cl 3.2.2 and adds the luminaires.
  4. Illuminance limit. Table 3.2 gives the vertical illuminance limit for the zone and period.
  5. Intensity limit. Table 3.3 gives the intensity limit for one luminaire. The tool uses the Level 1 value.
  6. Upward light ratio. Cl 3.3.1.8.2 gives the share of lumens above the horizontal. Table 3.2 gives the limit.
StepTable or clauseWhat it decides
ZoneAS/NZS 4282:2023 Table 3.1The environment class of the site
Illuminance at the windowCl 3.3.1.3The vertical light on the window
Illuminance limitTable 3.2The most light allowed at the window
Intensity limitTable 3.3The most intensity from one luminaire
Upward light ratioCl 3.3.1.8.2The share of light sent above the horizontal

Worked example

  • Two floodlights at a window 10 m away. Each unit gives 10,000 lm, mounted at 6 m and tilted 30°. Zone A2 applies outside the curfew. The tool gives 47.67 lx at the window against a limit of 5 lx, so it fails. The intensity of 3,143 cd is under the limit of 7,500 cd. The upward light ratio is 0.020 against 0.01, so that check also fails.

Limits

The result is a point-source estimate. A site measurement rules. The tool uses a lobe in place of the photometric file from the maker. Use the maker intensity table when you have it. Only direct light counts. Reflected light and obstructions are not modelled.

Level 1 intensity applies. Level 2 needs a precedent from existing lighting (Cl 3.2.5). Tilting a luminaire can raise the upward fraction, so type the value at the aiming angle.

See also: Obtrusive light and the 4282 zones, Car park floodlight obtrusive light at a boundary and the lighting lumen tool.

Pātai

He āwhina hoahoa te hua. Manatokohia ki te paerewa o nāianei.

Ko tēhea zone taiao e pā ana ki taku wāhi?

Ka whai te rohe i te whakamahere mahere o te takiwā, tae atu ki ngā rohe kei te heke mai. Ko te nuinga o ngā kāinga he A3, ko ngā takiwā tuawhenua koraha me ngā takiwā tata-tuawhenua he A2, ā, ko ngā pokapū tāone me ngā takiwā ahumahi he A4. Pātaihia te kaunihera ina kāore i te mārama.

He aha te curfew?

Ko te curfew te wā pō roa ina pā ngā tepe iti. Ki te kore te kaunihera, te whakaaetanga e whakatakoto ana i ētahi atu hāora, tangohia hei 11 p.m. ki te 6 a.m. Whakahohea te curfew hei arotake i ngā rama e noho tonu ana i taua wā.

He aha te kī a te taputapu he estimate tana whakautu?

Ka whakaaro ia ki ia rārangi luminaire hei tohu kotahi me te taka rino. He ripanga kaha tōna a te floodlight pono, ā, he pakitara, rākau me ngā whakaata tō te wāhi. Whakamahia he tātaitanga photometric, he ine wāhi rānei mō te whakautu whakamutunga.

He aha te wāhanga whakarunga o tētahi luminaire?

Te wāhanga o ōna lumens e wehe atu ana i runga i te horizontal i te koki aiming. He 0 te luminaire full cut-off kua whakatakotoria tapatapa. Ka taea e te tilt ki runga o tētahi floodlight te whakapiki, nō reira tangohia te tauāhua mai i ngā raraunga a te kaihanga i te tilt kua whakaurua.

He aha ngā tepe kaha Level 1 me Level 2?

I waho o te wā rongoroa, ka hoatu a Table 3.3 i ngā rohe kaha e rua. Ka pā te Taumata 1 ki te rama hou. He teitei ake te Taumata 2, ā, me whai tauira mai i te rama o tata nei. Ka arotake te taputapu i te Taumata 1.

Ngā tauira mahi

Kōrero o muri

Ngā Clause me ngā Table e pānuitia ana e tēnei taputapu

Ia Clause me Table, me te pēhea i manatokotia ai ia tētahi

Ngā tūtohi i arotakehia whakamutunga i te 1 Oct 2026.

He whai hua tēnei?

He pātai, he uara rānei e kitea ana he hē? Whakapā mai.