Ngā paerewa
Ko ēnei ngā tuhinga e tohutoro ana ngā tātaitai. He whārangi tōna ia tuhinga. Ko ia kōrero ki runga i tērā e kī ana i tā te taputapu e pānui ana i te clause, i te Table rānei. Kāore he kupu o tētahi paerewa e tuhia ana i konei. He taputapu hoahoa a AmpSize. Whakamanahia ngā hua ki te paerewa o nāianei.
392 urunga i roto i ngā tuhinga 24. 150 Table: 143 kua whakamanatia, 6 kua whakaputaina, 1 kāore e whakamanatia. Arotake whakamutunga 15 Oct 2026.
Hei tauira: cl 3.6.2, table 8.1, app p, 3008 table 13, whakawhenua.
AS/NZS 3000:2018
125 Clause me 51 Table · Tables 48 kua whakamanatia, 2 kua whakaputaina, 1 kāore e whakamanatia · Checked 15 Oct 2026
Ko ngā ture waea. Ka whakamahi AmpSize i tēnei paerewa mō ngā tirohanga e tika ai te ara iahiko. Ka uru ki reira te iahiko me kawe e te taura, te rohe heke voltage, te loop impedance me te maximum demand mō te whakaurunga.
AS/NZS 3008.1.2:2017
6 Clause me 16 Table · Tables 16 kua whakamanatia · Checked 26 Sept 2026
Te paerewa kōwhiri taura mō Aotearoa. Ka whakamahi te AmpSize i a ia mō ngā raraunga kaikawe: ngā reiti iahiko, te aukati me te reactance, ngā derating factors mō te ara, me te short-circuit k factor.
AS/NZS 3008.1.1:2017
16 Table · Tables 16 kua whakamanatia · Checked 26 Sept 2026
The cable selection standard for Australia, superseded by the 2025 edition; selectable for older designs. A cable tool reads it when the Standard is AU and the Edition is 2017. A link or save with no edition reads it too. It supplies current ratings, resistance and reactance, the derating factors for the route, and the short-circuit k factor.
AS/NZS 3008.1.1:2025
3 Clause me 22 Table · Tables 22 kua whakamanatia · Checked 27 Sept 2026
Te paerewa kōwhiri taura mō Ahitereiria, putanga 2025. Ka tīmata ngā mahi AU hou i te taputapu taura ki tēnei. Ka hōmai i ngā reiti iahiko, te aukati me te reactance, ngā correction factors mō te ara, me te K. Ka pānui te taputapu Rahi Taura DC i āna reiti d.c. me te heke voltage d.c.
AS/NZS 4777.1:2016
1 Clause
Te paerewa hononga kōpuku mō ngā pūnaha pūngao inverter. Ka whakamahi te AmpSize i a ia mō te rohe piki voltage i te taura i waenga i tētahi inverter me te wāhi puna.
IEC 60255-151:2009 / IEEE C37.112-2018
1 Clause me 1 Table · Tables 1 kua whakamanatia · Checked 26 Sept 2026
Ngā paerewa e rua e tautuhi ana i ngā āhuatanga inverse-time overcurrent. Ka whakamahia e AmpSize hei tuhi i ngā pīkiti trip relay, hei ine i te grading margin i waenga i ngā relay.
IEEE 1584-2018
1 Clause me 5 Table · Tables 5 kua whakamanatia · Checked 1 Oct 2026
Te aratohu tātaitanga mōrea arc flash, putanga 2018. Ka whakamahi te taputapu arc flash i tōna tauira mai i te taunoa mō te incident energy, te rohe me te karaehe PPE. Kua whakamanatia ōna tūtohi ki ngā whārangi kua tāngia.
IEEE 1584-2002
1 Clause me 1 Table · Tables 1 kua whakaputaina · Checked 1 Oct 2026
Te putanga 2002 kua whakakapia o te aratohu Arc Flash. Ka pupuri te taputapu Arc Flash i tana tauira hei kōwhiringa mō ngā rangahau tawhito. Ko tētahi hono, tiakitanga rānei kāore he tauira, ka pānui i a ia, nō reira kāore he hua kua tiakina e rerekē.
Electricity (Safety) Regulations 2010
8 Clause me 4 Table · Tables 4 kua whakamanatia · Checked 26 Sept 2026
Ko ngā ture a Aotearoa e tū ana i runga i ngā ture waea. Ka whakamahi te AmpSize i ngā paepae tono me ngā wā tiwhikete me ngā rekoata e mau ana, hei whakaatu i te huarahi mahi e haere ai tētahi whakaurunga, me te tiwhikete e hiahiatia ana mō te mahi. Ka pānui te pepa whakamātautau kaupapa i ngā arotake i mua i te hononga (reg 73A). Kia mōhio: ko te puka whakamanatanga EWRB e tohu ana i AS/NZS 3019:2007, engari ko te Schedule 2 e tohu ana i AS/NZS 3019:2022.
HELUKABEL and LAPP catalogues 2024
2 Table · Tables 1 kua whakamanatia, 1 kua whakaputaina · Checked 1 Oct 2026
Ngā katalōgi a ngā kaihanga taura. Ka whakamahia e AmpSize mō ngā hanganga screen, mō ngā āhuatanga taura e kāore ai he paerewa e whakaraupapa ana, me te tawhiti i waenga i ngā taura pūngao me ngā taura raraunga. He raraunga kaihanga ēnei, ehara i te paerewa, ā, ka kī ngā hua katoa e pānui ana i aua mea i tērā.
Industrial communications sources 2019-2024
1 Table · Tables 1 kua whakaputaina · Checked 1 Oct 2026
Ngā pukapuka aratohu a ngā kaihanga taura, me tētahi akoranga whakapakari tonu. Ka whakamahia e AmpSize mō ngā tepenga roa interface, ngā whakaritenga screen me ngā hanganga taura, nā te mea kāore he paerewa comms tā. Ka kī ngā hua katoa e pānui ana i aua mea i tērā.
AS/NZS 3760:2022
5 Clause me 3 Table · Tables 3 kua whakamanatia · Checked 1 Oct 2026
Te paerewa mō te whakamātautau me te tirotiro i ngā taputapu hiko kei te mahi, i pānuitia i tā rātou tānga me Amendment 1. Ka whakamahia e AmpSize mō te wā whakamātau anō o ia taiao, me te rohe paahi o ia whakamātautau kei te mahi. Ki te putanga 2010, ka mau tonu ngā rohe me ngā wā. Ka piki te rohe wā o waho mō tētahi RCD 30 mA hanga pūmau mai i te 150 ms ki te 300 ms. Ka pānui te taputapu Ngā Tae Kaikawe i ngā tae taura ngāwari, ngā tae o nāianei me ngā tae kua whakakapia.
NZS 4512:2010
15 Clause me 5 Table · Tables 5 kua whakamanatia · Checked 26 Sept 2026
Te paerewa o Aotearoa mō ngā pūnaha pūoho ahi me ngā pūnaha kitenga. Ka whakamahi a AmpSize i a ia mō te taumata pēhanga oro e tika ana kia tae ki te taputapu pūoho ā-rongo. Ka pānui a AmpSize i taua taumata mō tētahi rūma, mō tētahi pae moenga, mō tētahi mahau. Ka pānui hoki i te taumata taiao e tono ana kia whai taputapu pūoho ā-kite.
AS/NZS 3012:2019
11 Clause me 4 Table · Tables 4 kua whakamanatia · Checked 1 Oct 2026
Ka pānui a AmpSize i tēnei paerewa mō ngā mahi hiko i tētahi wāhi hanga, i tētahi wāhi whakahoro whare rānei. Ka uhi ia i ngā whakaritenga puna hiko e whakaaetia ana i reira, i te whakamaru RCD me ngā wā manatoko ā-wā. Ka uhi ano ia i te roa o te ara taura wāhi hanga, o te taura rānei. Ko te taura o tētahi huinga socket-outlet ka nekehia, 2 m te nui rawa, ka tatau ki taua ara taura. Ko ia uara ka tango a AmpSize mai i tērā i pānuitia mai i ngā whārangi rendered o te putanga 2019 me Amendment 1 kua whakauru. I te putanga 2010 i pānuitia e AmpSize i mua, e tika ana ngā tatauranga; ka huri a Table 3 hei Table 6, ka huri a Table 2 hei Table 7, ka whakanumerahia anō a Section 3, ā, ka uru tētahi exception mō Aotearoa anake ki a Cl 2.4.6.1.
AS/NZS 3002:2021
11 Clause me 1 Table · Tables 1 kua whakamanatia · Checked 1 Oct 2026
Te paerewa mō ngā whakaurunga hiko i ngā hākari, i ngā whakaaturanga me ngā carnival. Kei a AmpSize ngā whārangi tā 1 ki te 21 o te paerewa whārangi 84. Nō reira ka whakamahi ia i ngā tau puna hiko, RCD, underground, aerial me enclosure o Section 2 me 3 anake.
AS/NZS 1680.1:2006
2 Table · Tables 1 kua whakamanatia, 1 kua whakaputaina · Checked 1 Oct 2026
Ngā mātāpono whānui mō te rama o roto me te wāhi mahi. Ka pānui te taputapu lumen method i ōna karaehe illuminance me ōna teitei mokowā mahi. Kua whakamanatia a Table 3.1 ki te whārangi kua tāngia. Kei te ahu mai anō a Table 3.2: he rerekē tana ratio mokowā tata, ā, e tatari ana ki tētahi atu pūtake tāngia.
AS/NZS 1158.1.2:2010
1 Table · Tables 1 kua whakamanatia · Checked 1 Oct 2026
Te aratohu hoahoa mō te rama rori. Ka pānui te taputapu lumen method i ōna factor tiaki luminaire anake. Nā tētahi pānui tuarua o te whārangi kua tāngia i whakamanatia ngā factors katoa e toru tekau.
AS/NZS 4282:2023
5 Clause me 4 Table · Tables 4 kua whakamanatia · Checked 1 Oct 2026
Te paerewa mō ngā pānga obtrusive o te rama ā-waho. Ka pānui te taputapu Obtrusive Light i ōna rohe taiao me ōna rohe mō te rama ki te matapihi o tētahi hoa tata, me te rama ki runga. Kua whakamanatia ōna Table e whā: e rua ngā pānui motuhake ki ngā whārangi tā e rite ana ki ia uara.
AS/NZS 5033:2021
20 Clause me 5 Table · Tables 5 kua whakamanatia · Checked 2 Oct 2026
Te paerewa mō te whakaurunga o ngā PV array. Ka pānui te taputapu Rahi PV String i āna whakatika voltage, ōna rohe voltage me ngā tau iahiko string. Ka pānui te taputapu PV Array Isolator me te Whakawhenua i āna tau isolator, enclosure me te whakawhenua, me tana table earth fault interrupter. Kua whakamanatia katoatia ki ngā whārangi tā.
AS/NZS 4777.2:2020
1 Clause
Te paerewa mō ngā inverter e hono ana ki te grid. Ka pānui te taputapu Rahi PV String i ngā reiti anake e tohua ana ki tētahi inverter.
AS/NZS 5139:2019
14 Clause me 3 Table · Tables 3 kua whakamanatia · Checked 2 Oct 2026
Te paerewa mō te whakaurunga o ngā pūnaha pākahiko me ngā taputapu hurihuri power. Ka pānui te taputapu Pākahiko Kāinga i ōna ture wāhi Section 4 mō tētahi Pākahiko Kāinga katoa-i-tahi. Ka ine te Arotake Wāhi Pākahiko i tētahi wāhi hanga ki ia tētahi o ēnei. Kāore a AmpSize e pupuri ana i Amendment 1 (2025), nō reira tirohia mēnā kua rerekē.
AS/NZS 3017:2022
12 Clause me 1 Table · Tables 1 kua whakamanatia · Checked 1 Oct 2026
Te aratohu whakamanatanga whakaurunga mā te tirotiro me te whakamātautau. Ka tohu te taputapu Ngā Hua Whakamātautau i a ia i te taha o AS/NZS 3000 Section 8 ina rite ana ōna tau. Ko te tūtohi loop impedance he kua whakapōtaetia, nō reira ka noho a Section 8 hei tohutoro mō Zs. Ka pānui te taputapu Rārangi Whakamātautau i tana raupapa whakamātautau, me tana hua RCD mō tētahi pepa Ahitereiria.
AS 60529:2004
2 Clause me 1 Table · Tables 1 kua whakamanatia · Checked 1 Oct 2026
Ka whakahua a AmpSize i tēnei tuhinga i āna hua.
Nexans Olex The Handbook:2017
1 Table · Tables 1 kua whakamanatia · Checked 1 Oct 2026
Ka whakahua a AmpSize i tēnei tuhinga i āna hua.
Ngā paerewa i whakatauritea
- AS/NZS 3008.1.1 vs 3008.1.2: AU and NZ conditionsThe AU part of AS/NZS 3008.1 rates cable at 40 °C air and the NZ part at 30 °C. One 32 A circuit needs 6 mm² in Australia and 4 mm² in New Zealand.
- AS/NZS 3008 vs BS 7671: cable sizing comparedHow BS 7671 and AS/NZS 3000 with AS/NZS 3008.1 size a cable, where they differ, and why a BS current rating never converts into an AS/NZS one.
- IEC 60364 and the Wiring RulesIEC 60364 is the international series that AS/NZS 3000 stays aligned with. See how its parts are numbered, what TN-C-S, TT and IT mean, and where MEN fits.
- AWG and the NEC for NZ and AU electriciansAWG sizes and the NEC set against AS/NZS 3000 and 3008.1. A gauge converts to mm², but its rating does not, and the NEC 3 % drop figure is only a note.
- KuputakaNgā kupu e whakamahia ana e ngā tātaitai me ngā aratohu, ia kupu i roto i ngā whiu poto e rua.
Ngā whakaaro o muri i ēnei wāhanga
- Construction site supplies: AS/NZS 3012What AS/NZS 3012:2019 asks of the electrical supply on a construction or demolition site, from the supply and the RCDs to cords, generators and testing.
- Correction factors in the 2017 and 2025 editionsWhat each AS/NZS 3008 correction factor does, how the factors multiply, and which values changed when AS/NZS 3008.1.1:2025 replaced the 2017 tables.
- Who may do electrical work in NZThe regulations that govern prescribed electrical work and its certification in New Zealand, named by number, with the paperwork abbreviations explained.
- PV array isolators and earthingHow parallel strings feed a fault, what Ithe, Ie and make and break mean for a d.c. isolator, and how AS/NZS 5033 earths and alarms a PV array.
Ngā tauira mahi e tohu ana ki era
- Builder's pole: supply, RCDs and cord lengthsA builder's pole for a house build, worked to AS/NZS 3012:2019. The supply it may take, the 30 mA RCDs, the Table 1 cord lengths and the test intervals.
- Three circuits in a hot ceiling: correction factorThree 32 A circuits in conduit across a 40 °C and a 50 °C ceiling space, worked with the NZ 2017 tables and again with AS/NZS 3008.1.1:2025.
- AS/NZS 3008.1.2 Tables 22 to 29: deratingWhat the derating tables govern, how ambient and grouping combine into one factor, and a 63 A feeder whose capacity falls to 78.85 A on 35 mm² copper.