Ngā wā aromatawai wā-wā
Pānuitia te wā aromatawai e kī ana te reg 75 me te NZS 4512.
Reads Electricity (Safety) Regulations 2010 and NZS 4512:2010. Tables checked 26 Sept 2026.
Whakamātau mahi 6
Ka whakakī ia mahi i ngā uara tauira. Whakakapia ērā ki ō uara.
- Find the inspection interval for a marinaHow often a marina installation must have an assessment in NZ.
- Find the interval for a construction siteThe verification intervals for a construction site.
- Find the interval for a carnivalHow often show wiring must have an assessment.
- Find the interval for a hazardous areaThe inspection standard for a hazardous area.
- Find the interval for a medical areaThe assessment a medical installation must have.
- Find the fire alarm test intervalsThe monthly and annual checks NZS 4512 lists.
Ngā whakauru
He tauira mahi me ngā whakauru taunoa.
- Momo whakauru
- Papa pātaka, whakaurunga hiko iti
Maximum interval reg 75(1) states, low voltage installation
5 years maximum
- Whakaurunga
- Papa pātaka, whakaurunga hiko iti
- Paerewa i whakaingoatia
- AS/NZS 3001.1
- Tohutoro
- Electricity (Safety) Regulations 2010 reg 75(1)(a)
- Rekoata aromatawai e puritia ana mō, ture 75(4)(d)
- 3 tau
He āwhina hoahoa tēnei hua. Manatokohia ki te paerewa o nāianei.
Ngā hīkoi tātaitanga
- WhakauruPapa pātaka, whakaurunga hiko iti
Electricity (Safety) Regulations 2010 reg 75(1)(a)
- Paerewa ingoaAS/NZS 3001.1
Electricity (Safety) Regulations 2010 reg 75(1)(a)
- Wā nui rawa e kī ana te reg 75(1), low voltage installationHua5 tau te nui rawa
Electricity (Safety) Regulations 2010 reg 75(1)(a)
- Record of assessment e pupuritia ana mō, ngā tau3
Electricity (Safety) Regulations 2010 reg 75(4)(d)
Mō tēnei tātaitai
How this is calculated
The tool looks up the periodic assessment interval for a site type. It reads Electricity (Safety) Regulations 2010 reg 75 and points at the standard that reg 75 names.
- Installation. You pick the site type, such as a caravan park. The tool finds its entry in reg 75(1)(a).
- Standard named. It gives the standard that the entry names for the assessment.
- Interval. It gives the maximum interval that reg 75(1) states for a low voltage installation.
- Record. It gives how long the record of assessment is kept, from reg 75(4)(d).
- Fire alarm. For a fire alarm system, it adds the NZS 4512 intervals.
Worked example
- Caravan park. The tool names AS/NZS 3001.1. The maximum interval is 5 years. The record is kept for 3 years.
Limits
The tool points at the regulation. It gives no ruling on a site or a system. Reg 75(2) and reg 75(3) cover who carries out the assessment. Reg 75(8) covers how the intervals sit against the standard. The tool holds none of that detail. It read the regulations as at 15 January 2026. Check for a later version.
Use the result to plan the next assessment. The tool gives the maximum interval the regulation states. A shorter interval can apply to your site, because the owner or an insurer can ask for one. The record of assessment is a separate document. Keep it for the period the tool gives. The tool applies to New Zealand only. It has no Australian interval.
See also: Regulatory pathway, Regulations 57 and 59 explained and Who may do electrical work in NZ.
Pātai
He āwhina hoahoa te hua. Manatokohia ki te paerewa o nāianei.
He aha te auau o te aromatawai i tētahi papa caravan, marina poti rānei?
Ka hoatu a Electricity (Safety) Regulations 2010 reg 75(1)(a) i te 5 tau hei wā roa rawa mō tētahi whakaurunga papa caravan voltage iti. Ka whakaingoa i AS/NZS 3001.1. Ka hoatu a reg 75(1)(b) i te 5 tau ōrite mō tētahi whakaurunga marina poti voltage iti, ā, ka whakaingoa i AS/NZS 3004.1. Ka whakaatu a AmpSize i ngā tauanga, kāore ia e whakatau ture.
He aha te kore pūrongo ai e te taputapu i tētahi wā mō ētahi wāhi?
Reg 75(1)(c), (e) me (f) kāore he wā e kīa ana. Ia tētahi e whakaingoa ana i tētahi paerewa: AS/NZS 3012, AS/NZS 60079.17 mō ngā wāhi mōrearea ehara i te kāinga, NZS 6115 rānei, AS/NZS 3003. Ko tētahi wā ka ahu mai i taua paerewa, ā, kāore a AmpSize e pupuri ana i tētahi tauanga mai i reira. Ehara te kore kī i konei i te whakaurunga i waho o reg 75: tirohia reg 75(5) me reg 75(8).
He aha ngā wā mō ngā taputapu pōkai?
Ka ahu mai ēnei i AS/NZS 3760 Table 4, e ai ki te taiao me te karaehe taputapu. Whakamahia te taputapu Test and Tag o AmpSize mō ēnei. Ka uru tēnei taputapu ki ngā whakaurunga e rārangi ana reg 75, me ngā wā tirotiro i NZS 4512:2010 Part 6.
He whakataunga tēnei mō tētahi wāhi?
Kāo. Ka whakaingoa e te taputapu te ture, te clause rānei, ā, ka pūrongo i te wā kua whakaritea ki reira. Kāore ia e aromatawai i tētahi wāhi, ehara hoki i te tohutohu ture. Ko te reg 75(2), te reg 75(3) me te reg 75(4) e pā ana ki te tangata e mahi ana i te aromatawai me te record of assessment, ā, kāore a AmpSize e pupuri ana i ērā kōrero katoa.
Kia pēhea te roa e pupuri ana te rekoata aromatawai?
Ka kī a reg 75(4)(d) i te 3 tau, ā, ka whakaingoa i te tuku kape ki WorkSafe hei whiringa. Ka whakatika a reg 75(4)(b) i ngā mea e kīa ana e te rekoata. Pānuitia reg 75(4) mō ngā kōrero. Ka whakaatu a AmpSize i te tauanga 3 tau anake.
Ngā Clause me ngā Table e pānuitia ana e tēnei taputapu
- Electricity (Safety) Regulations 2010 reg 75Periodic assessment of installations
- NZS 4512:2010 Cl 602Fire alarm monthly checks
- reg 75Periodic assessment intervals for special installations
- Cl 602, Cl 603Fire alarm monthly and annual check intervals
Ia Clause me Table, me te pēhea i manatokotia ai ia tētahi
Ngā tūtohi i arotakehia whakamutunga i te 26 Sept 2026.
Ngā taputapu hononga
- Huarahi tiwhikete hikoFind the paperwork for a job in NZ or Australia.Electricity (Safety) Regulations 2010
- Kaitirotiro segregation and separationCheck what may share an enclosure and the separation.AS/NZS 3000
- Tātaitai kōwhiri RCDCheck if an RCD is required and test the trip time.AS/NZS 3000Electricity (Safety) Regulations 2010
He whai hua tēnei?
He pātai, he uara rānei e kitea ana he hē? Whakapā mai.