Arotake Obtrusive Light
Tirohia te rama o waho i tētahi matapihi rohe e ai ki AS/NZS 4282.
Reads AS/NZS 4282:2023. Tables checked 1 Oct 2026.
Whakamātau mahi 7
Ka whakakī ia mahi i ngā uara tauira. Whakakapia ērā ki ō uara.
- Check a car-park floodlight at a boundaryWhether a 20 000 lm floodlight 15 m from an upstairs window passes after the curfew.
- Check a bollard path at a boundaryWhether a 500 lm bollard 5 m from a neighbour’s window passes in zone A3.
- Check a tennis court floodlightWhether a 40 000 lm floodlight 20 m from a window passes.
- Check a security light on a houseWhether a 2000 lm wall light 8 m from a neighbour passes.
- Check a light in a rural zoneThe limits for a 5000 lm floodlight 30 m from the boundary in dark zone A1.
- Check a loading dock before the curfewA dock floodlight against the pre-curfew limit.
- Check the upward light of an uplightThe upward light ratio of a façade uplight.
Ngā whakauru
He tauira mahi me ngā whakauru taunoa.
- Te rohe taiao
- A2, Low district brightness
- I te wā kati pō
- Kāo
- Tawhiti ki te rohe
- 10 m
- Teitei o te pūtahi matapihi
- 1.5 m
- Ngā whakarāmaha
- 1 rārangi
Te rama poutū i te matapihi
47.67lx
- Te rohe o te rama poutū
- 5lx
- Te kaha nui rawa ki te matapihi
- 3,143cd
- Te rohe kaha ia rama
- 7,500cd
- Te ōwehenga o te māramatanga ki runga
- 0.020
- Te rohe o te ōwehenga o te māramatanga ki runga
- 0.01
He āwhina hoahoa tēnei hua. Manatokohia ki te paerewa o nāianei.
Ngā hīkoi tātaitanga
- Rohe taiaoA2, Low district brightness
AS/NZS 4282:2023 Table 3.1
- WāI waho o te wā aukati
AS/NZS 4282:2023 Cl 3.2.4
- Tauwhiwhi tiaki1
AS/NZS 4282:2023 Cl 3.2.2
- Pūtahi matapihi10 m out, 1.5 m up
AS/NZS 4282:2023 Cl 3.3.1.3
- Kaha teitei I04,775cd
- Koki i tawhio atu i te aho35.8°
- Kaha ki te matapihi3,143cd
AS/NZS 4282:2023 Cl 3.3.1.3
- Ev i te matapihi, 2 × 23.836 lx47.67lx
AS/NZS 4282:2023 Cl 3.3.1.3
- Te rama poutū i te matapihiHua47.67lx
AS/NZS 4282:2023 Cl 3.3.1.3
- Te rohe o te rama poutū5lx
AS/NZS 4282:2023 Table 3.2
- Te kaha nui rawa ki te matapihi3,143cd
AS/NZS 4282:2023 Cl 3.3.1.3
- Te rohe kaha ia rama, Taumata 17,500cd
AS/NZS 4282:2023 Table 3.3
- Lumen i runga ake i te pae400lm
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Lumen katoa20,000lm
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Te ōwehenga o te māramatanga ki runga0.02
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Te rohe o te ōwehenga o te māramatanga ki runga0.01
AS/NZS 4282:2023 Table 3.2
Mō tēnei tātaitai
How this is calculated
The tool estimates the light a floodlight or bollard puts on a neighbour window. It checks the result against AS/NZS 4282:2023.
- Zone and period. You pick the environmental zone, A0 to A4, and whether the curfew applies. Table 3.1 defines the zones. Cl 3.2.4 sets the curfew period.
- Intensity toward the window. The tool takes the beam angle and the tilt of each luminaire. It finds the angle off the beam axis. It then reads the intensity at that angle from a simple lobe (Cl 3.3.1.3).
- Vertical illuminance. For each luminaire, it divides the intensity by the squared distance to the window. It applies the maintenance factor of Cl 3.2.2 and adds the luminaires.
- Illuminance limit. Table 3.2 gives the vertical illuminance limit for the zone and period.
- Intensity limit. Table 3.3 gives the intensity limit for one luminaire. The tool uses the Level 1 value.
- Upward light ratio. Cl 3.3.1.8.2 gives the share of lumens above the horizontal. Table 3.2 gives the limit.
| Step | Table or clause | What it decides |
|---|---|---|
| Zone | AS/NZS 4282:2023 Table 3.1 | The environment class of the site |
| Illuminance at the window | Cl 3.3.1.3 | The vertical light on the window |
| Illuminance limit | Table 3.2 | The most light allowed at the window |
| Intensity limit | Table 3.3 | The most intensity from one luminaire |
| Upward light ratio | Cl 3.3.1.8.2 | The share of light sent above the horizontal |
Worked example
- Two floodlights at a window 10 m away. Each unit gives 10,000 lm, mounted at 6 m and tilted 30°. Zone A2 applies outside the curfew. The tool gives 47.67 lx at the window against a limit of 5 lx, so it fails. The intensity of 3,143 cd is under the limit of 7,500 cd. The upward light ratio is 0.020 against 0.01, so that check also fails.
Limits
The result is a point-source estimate. A site measurement rules. The tool uses a lobe in place of the photometric file from the maker. Use the maker intensity table when you have it. Only direct light counts. Reflected light and obstructions are not modelled.
Level 1 intensity applies. Level 2 needs a precedent from existing lighting (Cl 3.2.5). Tilting a luminaire can raise the upward fraction, so type the value at the aiming angle.
See also: Obtrusive light and the 4282 zones, Car park floodlight obtrusive light at a boundary and the lighting lumen tool.
Pātai
He āwhina hoahoa te hua. Manatokohia ki te paerewa o nāianei.
Ko tēhea zone taiao e pā ana ki taku wāhi?
Ka whai te rohe i te whakamahere mahere o te takiwā, tae atu ki ngā rohe kei te heke mai. Ko te nuinga o ngā kāinga he A3, ko ngā takiwā tuawhenua koraha me ngā takiwā tata-tuawhenua he A2, ā, ko ngā pokapū tāone me ngā takiwā ahumahi he A4. Pātaihia te kaunihera ina kāore i te mārama.
He aha te curfew?
Ko te curfew te wā pō roa ina pā ngā tepe iti. Ki te kore te kaunihera, te whakaaetanga e whakatakoto ana i ētahi atu hāora, tangohia hei 11 p.m. ki te 6 a.m. Whakahohea te curfew hei arotake i ngā rama e noho tonu ana i taua wā.
He aha te kī a te taputapu he estimate tana whakautu?
Ka whakaaro ia ki ia rārangi luminaire hei tohu kotahi me te taka rino. He ripanga kaha tōna a te floodlight pono, ā, he pakitara, rākau me ngā whakaata tō te wāhi. Whakamahia he tātaitanga photometric, he ine wāhi rānei mō te whakautu whakamutunga.
He aha te wāhanga whakarunga o tētahi luminaire?
Te wāhanga o ōna lumens e wehe atu ana i runga i te horizontal i te koki aiming. He 0 te luminaire full cut-off kua whakatakotoria tapatapa. Ka taea e te tilt ki runga o tētahi floodlight te whakapiki, nō reira tangohia te tauāhua mai i ngā raraunga a te kaihanga i te tilt kua whakaurua.
He aha ngā tepe kaha Level 1 me Level 2?
I waho o te wā rongoroa, ka hoatu a Table 3.3 i ngā rohe kaha e rua. Ka pā te Taumata 1 ki te rama hou. He teitei ake te Taumata 2, ā, me whai tauira mai i te rama o tata nei. Ka arotake te taputapu i te Taumata 1.
Ngā tauira mahi
Kōrero o muri
Ngā Clause me ngā Table e pānuitia ana e tēnei taputapu
- AS/NZS 4282:2023 Cl 3.2.2Maintenance factor for obtrusive light
- AS/NZS 4282:2023 Cl 3.2.4Curfew and non‑curfew limits
- AS/NZS 4282:2023 Cl 3.2.5Level 1 and Level 2 intensity
- AS/NZS 4282:2023 Cl 3.3.1.3Illuminance and intensity at a window
- AS/NZS 4282:2023 Cl 3.3.1.8.2Upward light ratio of the system
- AS/NZS 4282:2023 Table 3.1Environmental zones
- AS/NZS 4282:2023 Table 3.2Light technical parameter limits
- AS/NZS 4282:2023 Table 3.3Maximum luminous intensities per luminaire
Ia Clause me Table, me te pēhea i manatokotia ai ia tētahi
Ngā tūtohi i arotakehia whakamutunga i te 1 Oct 2026.
Ngā taputapu hononga
- Tātaitai rahi tauraFind the smallest cable size that passes each check.AS/NZS 3008.1.2AS/NZS 3008.1.1AS/NZS 3000
- Tātaitai mokowā detector ahiDetector spacing and count for a room or corridor.NZS 4512
- Tātaitai EV charger circuitCheck EV chargers for spare capacity, cable size and RCD.AS/NZS 3000AS/NZS 3008.1.2AS/NZS 3008.1.1
He whai hua tēnei?