跳至内容
AmpSize

AS/NZS 1158.1.2:2010

Table 14.4

Typical luminaire maintenance factors

The lighting lumen method tool reads a luminaire maintenance factor here. You choose the lamp chamber class, the pollution category and the cleaning interval. The tool multiplies that factor by the lamp lumen maintenance factor you type, as the table leaves lamp depreciation out. The table is for road lighting, so check the factor for an interior.

已核验:对照印刷版标准阅读,页码 63。检查于 1 Oct 2026。

单位:Months month, Factor

这些是 AmpSize 所编码的数值。不转载标准原文。请依据现行标准核对。

返回 AS/NZS 1158.1.2:2010 页面上的对应卡片

30 行

Table 14.4, Typical luminaire maintenance factors
IpPollutionMonths (month)Factor
IP54high120.89
IP54high180.87
IP54high240.84
IP54high360.76
IP54high480.66
IP54medium120.9
IP54medium180.88
IP54medium240.86
IP54medium360.82
IP54medium480.76
IP54low120.92
IP54low180.91
IP54low240.9
IP54low360.88
IP54low480.86
IP6Xhigh120.91
IP6Xhigh180.9
IP6Xhigh240.88
IP6Xhigh360.83
IP6Xhigh480.75
IP6Xmedium120.92
IP6Xmedium180.91
IP6Xmedium240.89
IP6Xmedium360.87
IP6Xmedium480.84
IP6Xlow120.93
IP6Xlow180.92
IP6Xlow240.91
IP6Xlow360.9
IP6Xlow480.89