跳至内容
AmpSize

AS 60529:2004

Cl 4 and Tables 1 to 4

The IP code: characteristic numerals, additional and supplementary letters

The IP rating tool reads the IP code element by element: the first numeral for objects and access, the second for water, the additional and supplementary letters, and the dual codes.

已核验:对照印刷版标准阅读,页码 4, 5, 7–10 (PDF 12, 13, 15–18)。检查于 1 Oct 2026。

单位:Object mm mm, Angle deg degree

这些是 AmpSize 所编码的数值。不转载标准原文。请依据现行标准核对。

返回 AS 60529:2004 页面上的对应卡片

28 行

Cl 4 and Tables 1 to 4, The IP code: characteristic numerals, additional and supplementary letters
KindNumeralObject mmDustAccessTablePageAngle deg (degree)LetterJetsImmersionCodeRange
first0———Tables 1 and 27-8
first150—back-of-handTables 1 and 27-8
first212.5—fingerTables 1 and 27-8
first32.5—toolTables 1 and 27-8
first41—wireTables 1 and 27-8
first5—protectedwireTables 1 and 27-8
first6—tightwireTables 1 and 27-8
second0Table 39—
second1Table 39—
second2Table 3915
second3Table 3960
second4Table 39—
second5Table 39—
second6Table 39—
second7Table 39—
second8Table 39—
letterback-of-handTable 410A
letterfingerTable 410B
lettertoolTable 410C
letterwireTable 410D
supplementaryCl 4.25H
supplementaryCl 4.25M
supplementaryCl 4.25S
supplementaryCl 4.25W
dualCl 6957IPX5/IPX7versatile
dualCl 6967IPX6/IPX7versatile
dualCl 6958IPX5/IPX8versatile
dualCl 6968IPX6/IPX8versatile

读取它的工具 (1)