Tingnan ang outdoor light sa boundary window ayon sa AS/NZS 4282.

Reads AS/NZS 4282:2023. Tables checked 1 Oct 2026.

Mga input

Worked example gamit ang mga default na input.

Environmental zone
A2, Low district brightness
Sa panahon ng curfew
Hindi
Distansya sa boundary
10 m
Taas ng gitna ng bintana
1.5 m
Mga luminaire
1 row

Vertical illuminance sa bintana

47.67lx

Limitasyon ng vertical illuminance
5lx
Pinakamataas na intensity patungo sa bintana
3,143cd
Limitasyon ng intensity kada luminaire
7,500cd
Upward light ratio
0.020
Limitasyon ng upward light ratio
0.01

Design aid lang ang resultang ito. I-verify ito laban sa kasalukuyang standard.

Mga hakbang ng kalkulasyon

  1. Environmental zoneA2, Low district brightness

    AS/NZS 4282:2023 Table 3.1

  2. PanahonNasa labas ng curfew

    AS/NZS 4282:2023 Cl 3.2.4

  3. Maintenance factor1

    AS/NZS 4282:2023 Cl 3.2.2

  4. Gitna ng bintana10 m out, 1.5 m up

    AS/NZS 4282:2023 Cl 3.3.1.3

  5. Peak intensity I04,775cd
  6. Anggulo mula sa axis ng beam35.8°
  7. Intensity patungo sa bintana3,143cd

    AS/NZS 4282:2023 Cl 3.3.1.3

  8. Ev sa bintana, 2 × 23.836 lx47.67lx

    AS/NZS 4282:2023 Cl 3.3.1.3

  9. Vertical illuminance sa bintanaResulta47.67lx

    AS/NZS 4282:2023 Cl 3.3.1.3

  10. Limitasyon ng vertical illuminance5lx

    AS/NZS 4282:2023 Table 3.2

  11. Pinakamataas na intensity patungo sa bintana3,143cd

    AS/NZS 4282:2023 Cl 3.3.1.3

  12. Limitasyon ng intensity kada luminaire, Level 17,500cd

    AS/NZS 4282:2023 Table 3.3

  13. Lumens sa itaas ng horizontal400lm

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  14. Kabuuang lumens20,000lm

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  15. Upward light ratio0.02

    AS/NZS 4282:2023 Cl 3.3.1.8.2

  16. Limitasyon ng upward light ratio0.01

    AS/NZS 4282:2023 Table 3.2

Tungkol sa calculator na ito

How this is calculated

The tool estimates the light a floodlight or bollard puts on a neighbour window. It checks the result against AS/NZS 4282:2023.

  1. Zone and period. You pick the environmental zone, A0 to A4, and whether the curfew applies. Table 3.1 defines the zones. Cl 3.2.4 sets the curfew period.
  2. Intensity toward the window. The tool takes the beam angle and the tilt of each luminaire. It finds the angle off the beam axis. It then reads the intensity at that angle from a simple lobe (Cl 3.3.1.3).
  3. Vertical illuminance. For each luminaire, it divides the intensity by the squared distance to the window. It applies the maintenance factor of Cl 3.2.2 and adds the luminaires.
  4. Illuminance limit. Table 3.2 gives the vertical illuminance limit for the zone and period.
  5. Intensity limit. Table 3.3 gives the intensity limit for one luminaire. The tool uses the Level 1 value.
  6. Upward light ratio. Cl 3.3.1.8.2 gives the share of lumens above the horizontal. Table 3.2 gives the limit.
StepTable or clauseWhat it decides
ZoneAS/NZS 4282:2023 Table 3.1The environment class of the site
Illuminance at the windowCl 3.3.1.3The vertical light on the window
Illuminance limitTable 3.2The most light allowed at the window
Intensity limitTable 3.3The most intensity from one luminaire
Upward light ratioCl 3.3.1.8.2The share of light sent above the horizontal

Worked example

  • Two floodlights at a window 10 m away. Each unit gives 10,000 lm, mounted at 6 m and tilted 30°. Zone A2 applies outside the curfew. The tool gives 47.67 lx at the window against a limit of 5 lx, so it fails. The intensity of 3,143 cd is under the limit of 7,500 cd. The upward light ratio is 0.020 against 0.01, so that check also fails.

Limits

The result is a point-source estimate. A site measurement rules. The tool uses a lobe in place of the photometric file from the maker. Use the maker intensity table when you have it. Only direct light counts. Reflected light and obstructions are not modelled.

Level 1 intensity applies. Level 2 needs a precedent from existing lighting (Cl 3.2.5). Tilting a luminaire can raise the upward fraction, so type the value at the aiming angle.

See also: Obtrusive light and the 4282 zones, Car park floodlight obtrusive light at a boundary and the lighting lumen tool.

Mga tanong

Design aid ang resulta. I-verify ito laban sa kasalukuyang standard.

Aling environmental zone ang nalalapat sa site ko?

Sinusunod ng zone ang planning zoning ng lugar, kasama ang future zoning. Karamihan sa mga suburb ay A3, ang mga sparse rural at semi-rural na lugar ay A2, at ang mga town centre at industrial area ay A4. Magtanong sa council kung malabo ito.

Ano ang curfew?

Ang curfew ay ang late-night na panahon kung kailan nalalapat ang mas mababang limit. Maliban kung may ibang oras na itinakda ang council o ang consent, ituring ito bilang 11 p.m. hanggang 6 a.m. I-on ang curfew para suriin ang mga ilaw na nananatiling bukas sa loob nito.

Bakit tinatawag ng tool na estimate ang sagot nito?

Itinuturing nito ang bawat row ng luminaire bilang isang point na may makinis na beam. Ang totoong floodlight ay may sariling intensity table, at ang site ay may pader, puno at reflections. Gumamit ng photometric kalkulasyon o site measurement para sa panghuling sagot.

Ano ang upward fraction ng luminaire?

Ang bahagi ng lumens nito na lumalabas sa itaas ng horizontal sa aiming angle. Ang full cut-off luminaire na nakalagay nang patag ay may 0. Ang pagtagilid ng floodlight pataas ay maaaring magpataas nito, kaya kunin ang figure mula sa datos ng maker sa naka-install na tilt.

Ano ang Level 1 at Level 2 na intensity limit?

Sa labas ng curfew, nagbibigay ang Table 3.3 ng dalawang intensity limit. Ang Level 1 ay nalalapat sa bagong lighting. Ang Level 2 ay mas mataas, at nangangailangan ng precedent mula sa umiiral na lighting sa malapit. Level 1 ang sinusuri ng tool.

Mga worked example

Background

Mga clause at table na binabasa ng tool na ito

Bawat clause at table, kasama kung paano ito na-verify

Huling na-check ang mga table noong 1 Oct 2026.