AmpSize
Isang cable size calculator at 84 pa para sa New Zealand at Australia. Tinutukoy ng bawat resulta ang Clause at Table nito.
Libre ang bawat calculator. Hindi kailangan ng account para kalkulahin.
Android app sa Google Play- Size a cable for a shedThe smallest cable that carries the load over the run to a shed.
- Size a submain for a tenancyThe smallest three phase submain that passes each check, on AU 3008.1.1:2025.
- Size a battery cableThe d.c. cable size for a 3 m, 48 V battery run at 100 A.
- Size a cable for an EV chargerThe cable size for a 32 A charger on a 25 m run.
- Wire a houseRooms and points become circuits, cable sizes and a maximum demand.
- Check a long run for voltage dropThe voltage drop on the run, against the limit.
AmpSize sa loob ng 30 segundo
Isang job sa cable size calculator, mula sa mga input hanggang sa resultang maitatabi mo.
Naka-sort para sa lahat ng trade
Mga calculator
85 calculator
Mga cable
- Cable size
- Voltage drop
- Loop impedance
- Fault rating
- Conduit fill
- Voltage rise
- Underground cable
- Segregation and separation
- Maximum circuit length
- Simplified selector
- Minimum conductor size
- Imperial cable
- Comms cable selector
- Aerial clearances
- Site cord length
- Loop power budget
- DC cable size
- Correction factors
- Total voltage drop
- Conductor colours
- Cable tray fill
- Cable loss cost
Proteksyon
Mga load
Power
Solar
Kaligtasan
Mga guide
Lahat ng guide- Builder's pole: supply, RCDs and cord lengthsA builder's pole for a house build, worked to AS/NZS 3012:2019. The supply it may take, the 30 mA RCDs, the Table 1 cord lengths and the test intervals.
- Car-park floodlight: obtrusive light at a boundaryTwo 10 000 lm floodlights 10 m from a neighbour's window in zone A2, checked against AS/NZS 4282 for lux at the window, candela and the upward light ratio.
- Homeowner shed supply voltage drop over 60 mA 20 A single‑phase supply running 60 m to a shed on 6 mm² copper, with the drop, the percentage and the maximum length the AmpSize voltage drop engine returns.
- Commercial kitchen kW to amps full load currentTurning a 30 kW commercial kitchen nameplate load into 45.58 A at 400 V three phase, with the power factor step that a plain kW to amps sum leaves out.
- Generator fault current calculation at 400 VA 500 kVA 400 V standby set at 12 % subtransient reactance gives 721.69 A full load and 6014.07 A fault current, with the decay the figure leaves out.
- IEEE 1584-2002: arc flash model and limitsWhat the IEEE 1584-2002 empirical model governs, where it stops applying, and a 400 V switchboard study that lands on 7.54 cal/cm² at 455 mm.
Learn
Lahat ng learn page- Conduit fill and installation methodsHow the conduit space factor works, what the fill percent means against the 40 % limit, and how the install method names on site map to the 3008 columns.
- Current-carrying capacity and deratingWhy one cable size has many ratings. Install method, ambient, grouping, soil and depth, with a 25 A circuit that needs 10 mm² once the factors apply.
- Downlights and insulation: IC-4, CA90 and Non‑ICThe six recessed luminaire classes, what insulation may do around each, which a NZ or AU home may have, the default clearances, and the roof space warning sign.
- Home batteries and AS/NZS 5139How a home solar battery is sized in kWh, what usable, nominal, depth of discharge and round-trip efficiency mean, and where AS/NZS 5139 lets one go.
- Home battery location and clearancesWhere AS/NZS 5139 lets an all-in-one home battery go. Restricted places, 600 and 900 mm zones, the habitable room barrier, ceiling, IP codes and working space.
- How many circuits can go on one RCDThe AS/NZS 3000 Cl 2.6.2.4 arrangement rules in plain words, which circuits need a 30 mA RCD in NZ and AU homes, how RCBOs count, and why the rules exist.