Lumaktaw sa nilalaman
AmpSize

Power point location check

Power point malapit sa cooktop, gas cylinder, vent o lababo.

Reads AS/NZS 3000:2018. Tables checked 1 Oct 2026.

Mga input

Worked example gamit ang mga default na input.

Bansa
New Zealand
Accessory
Socket‑outlet (power point)
Malapit
Cooktop (bukas na ibabaw ng pagluluto)
Pahalang na distansya
300 mm
Taas mula sa sahig o lupa
1,100 mm
Taas ng cooking surface
900 mm
Range hood o cabinet sa itaas
0 mm
Ito ang cooktop switch
Hindi

Ang posisyong ito

Pinapayagan

Panuntunan
Cl 4.7.3
Figure
Figure 4.17

Design aid lang ang resultang ito. I-verify ito laban sa kasalukuyang standard.

Mga hakbang ng kalkulasyon

  1. Mula sa gilid ng cooking surface300mm
  2. Ipinagbabawal sa loob ng150mm

    AS/NZS 3000:2018 Cl 4.7.3

  3. Ipinagbabawal mula sa900mm

    AS/NZS 3000:2018 Cl 4.7.3

  4. Ipinagbabawal hanggang2,500mm

    AS/NZS 3000:2018 Cl 4.7.3

  5. Taas mula sa sahig1,100mm
  6. Ang posisyong itoResultaPinapayagan

    AS/NZS 3000:2018 Cl 4.7.3

Tungkol sa calculator na ito

How this is calculated

AS/NZS 3000 keeps socket‑outlets and switches out of a few places in a kitchen and around gas, and sets one rule near the floor. You pick the accessory, what it is near and the distances. The tool finds the rule, draws its zone and says whether the position is inside it.

Beside a cooktop, no socket‑outlet or switch may sit within 150 mm of the edge of an open gas or electric cooking surface. That band runs up from the cooking surface to the range hood, cupboard or ceiling above it, or to 2.5 m above the floor, whichever is lower. The cooktop's own switch must also be near it, in sight, not on the appliance and not reached across the cooking surface. The standard advises within 2 m, so the tool warns beyond that.

Around an outdoor gas cylinder, no ignition source may sit in the hazardous area. It is widest at the base and narrower at the top, 0.5 m above the cylinder, and an in-situ fill cylinder has a larger area than an exchange cylinder. The standard dimensions the base and the top. Between them the tool takes the edge as a straight line, as drawn, and says when a result rests on that reading. A gas relief vent has a zone ahead of it and a smaller one behind, scaled up for a vent over 50 mm. New Zealand adds an indoor cylinder compartment and the zone about a reticulated gas regulator.

Sinks, basins, baths and showers have zones of their own. The tool sends those to the wet area zones tool.

StepTable or clauseWhat it decides
Near the floorCl 4.4.2.2(b)How a low socket‑outlet is fitted
Beside a cooktopCl 4.7.3 and Figure 4.17The prohibited band beside and above the cooking surface
The cooktop switchCl 4.7.1Where the cooktop's own switch goes
An outdoor gas cylinderCl 4.18.2.1 and Figure 4.18The hazardous area by cylinder type
An indoor cylinderCl 4.18.3No ignition source in the compartment, New Zealand
A gas relief ventCl 4.18.4 and Figure 4.19The exclusion zone by vent size
A gas regulatorCl 4.18.5 and Figure 4.20The zone about the riser, New Zealand homes

Worked examples

Limits

The tool checks the rules named here. It does not check the hazardous area classification of Cl 7.7, equipment rated for a Zone 2 area, or the gas fitting standards. It does not set general mounting heights: AS/NZS 3000 sets none outside the rules above and Section 6. Measure on site where a result is close to a boundary.

See also: Power points near a cooktop, gas bottle and sink, Kitchen power points and the cooktop zone and Wet area zones.

Mga tanong

Design aid ang resulta. I-verify ito laban sa kasalukuyang standard.

Gaano kalayo dapat ang power point mula sa cooktop?

Hindi puwede ang socket‑outlet o switch sa loob ng 150 mm mula sa gilid ng bukas na gas o electric cooking surface. Umaabot ang zone mula sa cooking surface paitaas hanggang sa range hood, cupboard o kisame sa itaas, o 2.5 m sa ibabaw ng floor, alinman ang mas mababa.

Gaano kalayo dapat ang power point sa gas bottle?

Sa labas ng hazardous area ng AS/NZS 3000 Figure 4.18. Para sa exchange cylinder, umaabot ito ng 1500 mm sa base at 500 mm sa itaas, 0.5 m sa ibabaw ng cylinder. Para sa in-situ fill cylinder, 3500 mm at 1500 mm.

Gaano kalayo dapat ang power point sa sink?

Itinatakda ito ng AS/NZS 3000 sa Section 6, ayon sa zones sa paligid ng lababo o basin. Gamitin ang wet area zones tool na may napiling lababo. Sakop ng tool na ito ang cooktops, gas at sahig.

Saan ilalagay ang cooktop isolating switch?

Malapit sa cooktop, nakikita at madaling maabot, pero hindi sa mismong appliance at hindi kung saan kailangang umabot ang user sa ibabaw ng cooking surface. Nagpapayo ang standard na nasa loob ng 2 m. Hindi ito puwedeng nasa prohibited zone sa tabi ng cooktop.

Puwede bang ilagay ang power point malapit sa sahig?

Oo. Kapag nasa loob ng 75 mm mula sa sahig, ikinakabit ito para pahalang na mahila palabas ang plug, maliban kung floor socket‑outlet na ginawa para doon. May sariling floor clearance ang wet rooms sa Section 6.

Mga worked example

Background

Mga clause at table na binabasa ng tool na ito

Bawat clause at table, kasama kung paano ito na-verify

Huling na-check ang mga table noong 1 Oct 2026.

Nakatulong ba ito?