مخطط تصنيف IP ومفكّك الرموز
فكّ رمز IP واعثر على الأدنى المطلوب لموقع معيّن.
Reads AS 60529:2004 and AS/NZS 3000:2018. Tables checked 1 Oct 2026.
جرّب مشروعاً 4
تملأ كل مهمة قيماً توضيحية. استبدلها بقيمك.
- Read what IP44 meansEach digit of an IP code, by AS 60529.
- Check an outdoor power point codeAn IP44 socket‑outlet outside the eave area against IP33.
- Choose a code for a hosed areaThe least code for high-pressure hosing, and an IP66 light checked.
- Check a light for a sauna roomAn IPX4 light against the IPX4B or IP24 a sauna needs.
المدخلات
مثال محلول بالمدخلات الافتراضية.
- السؤال
- ماذا يعني رمز IP هذا؟
- رمز IP
- IP65
ماذا يعني الكود
Dust-tight · Water jets
- الأجسام الصلبة
- Dust-tight
- الوصول إلى الأجزاء الخطرة
- A wire
- الماء
- Water jets
هذه النتيجة أداة للتصميم. تحقق منها وفق المعيار الحالي.
خطوات الحساب
- الكودIP65
AS 60529-2004 Cl 4.1
- الرقم الأول 6Dust-tight; a wire
AS 60529-2004 Tables 1 and 2
- الرقم الثاني 5Water jets
AS 60529-2004 Table 3
حول هذه الحاسبة
How this is calculated
The tool answers two questions: what an IP code means, and which code a location needs.
To decode, it reads the code the way the IP code standard lays it out. After the letters IP come two characteristic numerals. The first, 0 to 6, covers solid objects and access to hazardous parts: the size of object kept out, and the part of a person kept off, from the back of a hand to a wire. The second, 0 to 8, covers water, from dripping to continuous immersion. An X stands for a numeral that is not stated. An optional additional letter, A to D, marks access protection better than the first numeral gives. Optional supplementary letters, H, M, S and W, add information for a product standard. A dual code such as IPX5/IPX7 meets both of its parts. Up to 6, a second numeral also meets every lower one, but a 7 or 8 alone is for immersion and does not meet water jets.
To select, the tool reads the least code the wiring rules name for the location, outside the zones around baths, showers, pools and spas. It says whether the clause is a requirement, a NOTE or an informative recommendation. With a device's code, it compares element by element: each numeral at or above the one required, and an access letter met by the letter or by the first numeral.
| Step | Table or clause | What it decides |
|---|---|---|
| Reading the code | AS 60529 Cl 4.1 | The numerals and letters, and X |
| Objects and access | AS 60529 Tables 1 and 2 | What the first numeral keeps out |
| Water | AS 60529 Table 3 and Cl 6 | What the second numeral resists, and dual codes |
| Access letter | AS 60529 Table 4 | What the additional letter keeps off |
| Enclosures | Cl 1.5.4.4 | The least code around live parts |
| Outdoor accessories | Cl 4.1.3 | The code outside the eave area |
| Switchboards | Cl 2.10.2.5 | Hosing, sprinklers and exits |
| Saunas and hosed areas | Cl 6.5.4.1 and Cl 6.7.4.1 | The code in the room or zone |
| Outdoor EV point | App P | The recommended code |
Worked examples
- IP65. Dust-tight, with no access even by a wire, and protected against water jets from any direction.
- IPX4B. No object numeral is stated. The letter B keeps a finger off, so access is by a finger at worst, and the code resists splashing water from any direction.
- An IP44 power point outside the eave. IP44 meets IP33, the code Cl 4.1.3 sets outside the area an eave protects.
- An IP67 light in a dairy hosed at high pressure. IP67 is below IPX6: a 7 alone is for immersion, not jets.
- A sauna light marked IPX4. IPX4 is below IP24 or IPX4B: the sauna also needs the finger kept off.
Limits
The tool reads AS 60529-2004, which stops the second numeral at 8; a 9 comes from a later IEC edition. It does not test anything: a code is what the maker has proven for the enclosure as tested. Drilling a drain hole, or a gland that does not seal, loses the code. For a bathroom, laundry, pool or spa, use the wet area zones tool: the code depends on the zone.
See also: IP ratings explained: each digit and letter, IP ratings for an outdoor point and a hosed shed and Wet Area Zones.
الأسئلة
النتيجة أداة للتصميم. تحقق منها وفق المعيار الحالي.
ماذا تعني IP65؟
الرقم الأول، 6، يعني محكم ضد الغبار، دون وصول إلى الأجزاء الخطرة حتى بسلك. والرقم الثاني، 5، يعني محمي ضد نفاثات الماء من أي اتجاه. يعرّف AS 60529 الاثنين.
هل IP67 أفضل من IP65؟
ليس للنفاثات. الرقم 7 أو 8 وحده للغمر، ولا يعدّه AS 60529 حماية من نفاثات الماء. والمنتج المعتمد للأمرين مزدوج الترميز، مثل IP65/IP67.
ما تصنيف IP الذي يحتاجه المقبس الخارجي؟
IP33 حيث يقع خارج المنطقة التي تحميها الحافة البارزة للسقف أو الشرفة، وفق AS/NZS 3000 Cl 4.1.3. داخل تلك المنطقة، تحت الجانب السفلي للحافة البارزة وخط بزاوية 30 درجة نحو الجدار، لا يحتاج الملحق إلى وسم IP.
ماذا تعني X والحروف؟
يرمز الحرف X إلى رقم غير مذكور. يدل حرف إضافي من A إلى D على حماية وصول أفضل مما يعطيه الرقم الأول. يضيف حرف تكميلي H أو M أو S أو W معلومات لمعيار المنتج.
ما تصنيف IP الذي أحتاجه في الحمام؟
يعتمد ذلك على المنطقة حول حوض الاستحمام أو الدش أو المغسلة. استخدم أداة مناطق الأماكن الرطبة: تحدد المنطقة من المسافات، وتعرض المتطلب الذي تشترطه تلك المنطقة.
أمثلة محلولة
الخلفية
البنود والجداول التي تقرأها هذه الأداة
- AS 60529-2004 Cl 4.1Arrangement of the IP code
- AS 60529-2004 Cl 6Second numeral: protection against water
- AS/NZS 3000:2018 IP codes by locationThe least IP code AS/NZS 3000 names for a location, outside the Section 6 zones
- AS 60529-2004 Cl 4 and Tables 1 to 4The IP code: characteristic numerals, additional and supplementary letters
كل البنود والجداول، مع طريقة التحقق من كل منها
آخر فحص للجداول في 1 Oct 2026.
أدوات ذات صلة
- مدقق مناطق الأماكن الرطبةFind the Section 6 zone, IP and RCD near water.AS/NZS 3000
- المسار التنظيمي للشهادات الكهربائيةFind the paperwork for a job in NZ or Australia.Electricity (Safety) Regulations 2010
- دليل ألوان الموصلاتFind wire colours for fixed wiring and cords, old and new.AS/NZS 3000AS/NZS 3760
هل كان هذا مفيداً؟
سؤال، أو قيمة تبدو خاطئة؟ اتصل بنا.