Cấp độ trung cấp
Các khái niệm đứng sau một công việc thực tế: phụ tải cực đại, tổng trở mạch vòng và các bảng lựa chọn cáp.
- Đọc 4 phútAS/NZS 3008.1.1:2025: what the AU part coversWhat AS/NZS 3008.1.1:2025 covers, a.c. to 0.6/1 kV and d.c. to 1500 V at 40 °C air and 25 °C soil, how its sections run, and where the d.c. tables are.

- Đọc 5 phútBattery classes and arc flash in AS/NZS 5139How AS/NZS 5139 classes a battery system by hazard and decisive voltage class, works its arc flash energy, and sets the PPE, consequence and home limits.

- Đọc 4 phútCable tray fill: one layer, tiers and groupingHow cables lie on a tray or ladder for AS/NZS 3008.1, touching or spaced, when a run needs another tier, and why there is no fill percentage to work to.

- Đọc 5 phútChecking an existing circuitThe five checks AmpSize runs on an installed circuit, from Iz and voltage drop to Zs and fault withstand, and what a site test adds that a calculation cannot.

- Đọc 4 phútChoosing a comms cable: length and screenCheck a comms cable run before you order it. Length limits for RS-485 and Ethernet, the 4-20 mA loop and the screen rule, with three worked runs.

- Đọc 6 phútConstruction site supplies: AS/NZS 3012What AS/NZS 3012:2019 asks of the electrical supply on a construction or demolition site, from the supply and the RCDs to cords, generators and testing.

- Đọc 4 phútControl panels and PLC wiringSegregation of LV and ELV in a control panel, terminal and numbering practice, panel earthing, and the 24 V DC voltage drop that long instrument loops fail on.

- Đọc 5 phútCorrection factors in the 2017 and 2025 editionsWhat each AS/NZS 3008 correction factor does, how the factors multiply, and which values changed when AS/NZS 3008.1.1:2025 replaced the 2017 tables.

- Đọc 5 phútDamp situations: the Section 6 zonesHow AS/NZS 3000 Section 6 zones the space around baths, showers, basins, spas, pools, fountains and saunas, how to read an IP code, and what A2 changed.

- Đọc 5 phútDC voltage drop and conductor resistanceWhy d.c. drop is 2 × I × R × L, why it has no reactance or power factor, and how the hot resistance, the cable tables, the limit and parallel cables change it.

- Đọc 3 phútEarthing an outbuilding: earth or its own MENWhen a shed or sleep-out takes an earth with its submain and when it may have its own MEN link and electrode, the PEN size, and the electrode depths to use.

- Đọc 5 phútGenerator sizing for motor startingWhy a motor's start, not its running load, often sets a generator's size. Running and starting kVA, voltage dip, starting methods and derating.

- Đọc 3 phútIB ≤ IN ≤ IZ: the overload rule on a 32 A circuitThe overload rule is IB ≤ IN ≤ IZ. A grouped 32 A circuit fails on 6 mm² and passes on 10 mm², with an IZ of 37.6 A. Why the order matters.

- Đọc 4 phútIEC 60364 and the Wiring RulesIEC 60364 is the international series that AS/NZS 3000 stays aligned with. See how its parts are numbered, what TN-C-S, TT and IT mean, and where MEN fits.

- Đọc 4 phútLighting layout and the lumen methodHow many luminaires does a room need? The lumen method from target lux to a grid, worked on an 8 m by 6 m office, with the checks the tool applies.

- Đọc 5 phútLoop impedance and disconnection timeZe, R1+R2, Zs and Ia, and the two disconnection times, worked on a 32 A curve C circuit over 30 m that returns 0.79 Ω against a 0.96 Ω limit.

- Đọc 4 phútMaximum demand and diversityWhy consumer mains are smaller than the sum of the loads. The four methods of Cl 2.2.2, the Table C1 groups, and a house that lands on 70.18 A.

- Đọc 4 phútMotor circuits and startingHow full load current sizes the cable and starting current sizes the device on a motor circuit, with a worked 22 kW 400 V motor and the cable the tool selects.

- Đọc 4 phútMotor starters, contactors and overload relaysHow to choose a motor starter: locked-rotor current, star-delta, soft starters, AC-3 and AC-23 duty, the overload relay and when motor protection applies.

- Đọc 3 phútMotor starting methods: current and torqueWhy a cage motor draws six or seven times full load current at start, and how star-delta, an autotransformer, a soft starter and a drive trade it for torque.

- Đọc 4 phútObtrusive light and the 4282 zonesHow AS/NZS 4282 limits spill light from outdoor lighting at a neighbour's window, by environmental zone A0 to A4, curfew, intensity and upward light ratio.

- Đọc 4 phútPower factor and reactive powerWhat power factor is, why a low one costs current and capacity, how a capacitor bank corrects it in steps, and when harmonics call for a detuned bank.

- Đọc 4 phútPV and inverter basicsHow a grid-connected PV system connects to an installation, why voltage rise sets the inverter cable, and which standards the AmpSize tools cannot quote.

- Đọc 4 phútPV array isolators and earthingHow parallel strings feed a fault, what Ithe, Ie and make and break mean for a d.c. isolator, and how AS/NZS 5033 earths and alarms a PV array.

- Đọc 3 phútPV string voltage and temperatureWhy a PV string's voltage rises in the cold and falls in the heat, how AS/NZS 5033 limits it, and how the string current, fuses and isolator follow.

- Đọc 4 phútRCD leakage and nuisance trippingWhy an RCD trips with no fault. Where standing leakage comes from, the one-third and one-half points of Cl 2.6.2.1, class limits against measured figures.

- Đọc 5 phútRCD types and where they are requiredType AC, A, F and B, what each one detects, and the clauses that place them. The fault path behind them, worked on a 20 A circuit over 25 m.

- Đọc 4 phútShort-circuit withstand and the k factorThe adiabatic check in plain terms: prospective fault current, clearing time and k, worked on 25 mm² copper XLPE at 10 kA for 0.1 s.

- Đọc 4 phútTesting to Section 8: what each test provesThe Section 8 test sequence, what each test shows, and how a calculated earth fault loop impedance compares with the value a tester reads on site.

- Đọc 4 phútUnderground cables and civil interfacesBurial categories, depth of cover, bedding and separation for underground cables, with a worked 100 A submain that changes size when the trench changes.

Công cụ tính mà các hướng dẫn này sử dụng
- Công cụ tính tiết diện cápTìm tiết diện cáp nhỏ nhất đạt mọi bước kiểm tra.
- Công cụ tính tiết diện cáp DCChọn cỡ cáp d.c. đến 1500 V theo dòng điện và sụt áp.
- Chớp hồ quang và cấp ắc quyDVC, cấp nguy hiểm, năng lượng chớp hồ quang và cấp PPE của ắc quy.
- Công cụ tính ắc quy năng lượng mặt trờiChọn cỡ ắc quy lưu trữ gia đình cho phụ tải buổi tối từ hệ mặt trời.
- Công cụ tính chớp hồ quangƯớc tính năng lượng chớp hồ quang và cấp PPE của nó.
- Độ lấp đầy máng cáp và thang cápChiều rộng máng hoặc thang cáp, số tầng, kg/m và hệ số đi chung nhóm.
- Công cụ tính hệ số hiệu chỉnhĐọc từng hệ số hiệu chỉnh và định mức mà cáp cần.
- Kiểm tra mạch hiện cóKiểm tra một mạch đã lắp đặt: cáp, thiết bị, sụt áp và Zs.
- Công cụ tính tổng trở mạch vòng sự cố chạm đấtKiểm tra tổng trở mạch vòng sự cố chạm đất so với Zs tối đa.
- Chọn cáp truyền thôngChọn cáp truyền thông và kiểm tra chiều dài tuyến cáp.
- Quỹ công suất cho mạch vòng 4–20 mAKiểm tra điện áp còn lại tại bộ truyền tín hiệu (transmitter) của mạch vòng 4–20 mA.
- Công cụ tính nguồn cấp công trườngQuy tắc nguồn cấp, RCD và thử nghiệm cho công trường.
- Công cụ tính chiều dài dây nguồn tại công trườngChiều dài tối đa mà dây nguồn hoặc cáp được phép đi trên công trường.
- Chu kỳ thử nghiệm và gắn thẻChu kỳ thử lại và giới hạn đạt cho thiết bị di động.
- Nguồn cấp thiết bị cầm tayĐọc danh sách bố trí nguồn cấp regs 88 đến 89A.
- Công cụ kiểm tra đi dây triển lãm và hội chợKiểm tra RCD cho đi dây triển lãm, cùng độ sâu và chiều cao đi dây tại khu triển lãm.
- Công cụ tính sụt ápTính sụt áp trên tuyến cáp và kiểm tra giới hạn.
- Công cụ tính dàn ắc quyTính dung lượng và thời gian tự chủ của dàn ắc quy cho một phụ tải.
- Công cụ tính dòng đầy tảiTính dòng đầy tải từ công suất, điện áp và số pha.
- Công cụ chọn nối đất lớp chống nhiễu cápTìm vị trí nối đất cho lớp chống nhiễu, dây thoát nhiễu (drain) hoặc lớp giáp.
- Công cụ kiểm tra vùng khu vực ướtTìm vùng Section 6, cấp IP và RCD gần nguồn nước.
- Công cụ tính chọn RCDKiểm tra xem có cần RCD không và thử thời gian cắt.
- Nối đất công trình phụNối đất nhà kho: nối đất đi cùng cáp cấp tủ phụ, hoặc MEN riêng của nó.
- Công cụ tính nối đất và liên kết đẳng thếChọn cỡ dây nối đất, dây nối đất chính và dây liên kết đẳng thế.
- Chọn công suất máy phát từ danh sách phụ tảiChọn cỡ máy phát từ danh sách phụ tải có khởi động động cơ.
- Công cụ tính dòng điện máy phátDòng đầy tải và dòng sự cố của máy phát từ công suất kVA.
- Công cụ tính động cơTìm dòng đầy tải, dòng khởi động và mômen của động cơ.
- Công cụ tính khả năng chịu ngắn mạch của cápKiểm tra dây dẫn có chịu được dòng sự cố không.
- Công cụ tính phụ tải cực đạiƯớc tính phụ tải cực đại cho phụ tải dân dụng hoặc không dân dụng.
- Công cụ tính chiếu sáng theo phương pháp quang thôngSố lượng đèn và lưới bố trí cho một phòng theo phương pháp quang thông.
- Công cụ tính công suất ba phaQuy đổi giữa công suất, dòng điện, điện áp và hệ số công suất.
- Công cụ tính mạch động cơCáp, aptomat, contactor và quá tải cho một động cơ.
- So sánh phương pháp khởi động động cơSo sánh khởi động DOL, sao-tam giác, khởi động mềm và khởi động bằng biến tần.
- Công cụ kiểm tra ánh sáng gây phiềnKiểm tra ánh sáng ngoài trời tại cửa sổ ở ranh giới theo AS/NZS 4282.
- Công cụ tính bù hệ số công suấtTìm công suất tụ bù (kVAr) để nâng hệ số công suất.
- Công cụ tính tăng ápTính tăng áp cho phát điện phân tán hoặc PV.
- Công cụ tính cầu dao cách ly và nối đất PVĐánh giá cáp dàn PV, cầu dao cách ly d.c. và nối đất.
- Công cụ tính chuỗi PVSố tấm mỗi chuỗi, dòng chuỗi và cầu dao cách ly cho dàn PV.
- Tổng dòng rò cho phép của RCD ở trạng thái thường trựcMột RCD chịu được bao nhiêu dòng rò thường trực.
- Kiểm tra bố trí RCDKiểm tra số mạch trên mỗi RCD và cách phân bổ chiếu sáng.
- Công cụ tính máy biến ápTính dòng đầy tải và tổng trở của máy biến áp.
- Công cụ kiểm tra kết quả thử nghiệmKiểm tra kết quả thử nghiệm đo được so với giới hạn của Section 8.
- Công cụ tính độ sâu cáp chôn ngầmĐộ sâu lớp đất phủ và khoảng cách cách ly đối với cáp chôn ngầm.
- Công cụ tính độ lấp đầy ống luồnKiểm tra bó cáp có vừa trong ống luồn không.