Engineer hướng dẫn
Kiểm tra thiết kế, lập bằng chứng và so sánh các tiết diện cáp ứng viên cho một công việc.
- Đọc 4 phútCar-park floodlight: obtrusive light at a boundaryTwo 10 000 lm floodlights 10 m from a neighbour's window in zone A2, checked against AS/NZS 4282 for lux at the window, candela and the upward light ratio.

- Đọc 3 phútGenerator fault current calculation at 400 VA 500 kVA 400 V standby set at 12 % subtransient reactance gives 721.69 A full load and 6014.07 A fault current, with the decay the figure leaves out.

- Đọc 3 phútIEEE 1584-2002: arc flash model and limitsWhat the IEEE 1584-2002 empirical model governs, where it stops applying, and a 400 V switchboard study that lands on 7.54 cal/cm² at 455 mm.

- Đọc 5 phútArc flash at a 48 V home batteryClass a 48 V lithium home battery with 6 kA at its terminals by AS/NZS 5139, find its arc flash energy and PPE level, then bring it down with fuses.

- Đọc 3 phútIEC 60255-151: IDMT curve constantsWhat IEC 60255-151 governs, which curve sets the IDMT tool carries, and a worked grading pair on standard inverse that clears in 0.21 s and 0.74 s.

- Đọc 3 phútArc flash boundary at a motor control centreArcing current, incident energy and arc flash boundary for a 400 V MCC at 25 kA with a 0.1 s clearing time, and why the equipment type moves the result.

- Đọc 4 phútSwitchboard fault rating at 25 kA for 1 sA 1 second withstand check at 25 kA on 185 mm² copper XLPE, returning a 174.83 mm² minimum size and a 26.46 kA withstand, with a thin margin explained.

- Đọc 3 phútDC isolator rating for a 10 kW solar arrayRate the d.c. isolator and size the frame earth for a four-string domestic array. Check one data sheet that passes and one that fails per pole.

- Đọc 3 phútSolar string sizing for a 600 V inverterHow many 49.5 V modules fit a string on a 600 V inverter at -5 °C? Work cold Voc, hot Vmp, the string current, fuses and the d.c. isolator by AS/NZS 5033.

- Đọc 3 phútStarting a loaded conveyorA 22 kW conveyor that needs 120 % torque to break away. Why star-delta and a soft starter will not start it, and what a drive or autotransformer does.

- Đọc 4 phútMotor circuit for a 15 kW pump: DOL or star-deltaSize a 15 kW 400 V pump circuit: cable, breaker, contactor and overload relay. Compare DOL, star-delta, soft starter and drive starts.

- Đọc 3 phútTransformer secondary fault current for 500 kVAA 500 kVA 11 kV to 400 V transformer at 6 percent impedance, worked through to 721.69 A of secondary full load current and 12,028.13 A of fault current.

- Đọc 3 phútFactory power factor correction: 250 kW at 0.78A 250 kW factory load at 0.78 power factor lifted to 0.95. The kvar, the capacitor steps, the current saved, the kVA released and why the bank is detuned.

- Đọc 3 phútFault level at a sub‑board, 300 kVA transformerWork the prospective fault current at a sub-board 45 m from a 300 kVA transformer, three-phase and phase-earth, and check 6 kA and 10 kA breakers against it.

- Đọc 4 phútAmpSize vs jCalc vs free cable sizing toolsCompare AmpSize with jCalc and other free cable sizing tools. One 63 A three-phase submain shows which checks decide a size, and what AmpSize leaves out.

- Đọc 3 phútArc flash incident energy at a 400 V switchboardA 400 V board with 20 kA bolted fault and 0.2 s clearing gives 6.23 cal/cm² at 455 mm, an arcing current of 9.64 kA and a 1395.97 mm boundary.

- Đọc 4 phútAS/NZS 3008.1.2 Table 52: the k factorWhat Table 52 governs, how the adiabatic check uses k, and a 10 kA fault cleared in 0.1 s that needs 22.11 mm² against an installed 25 mm² conductor.

- Đọc 3 phútIDMT curve grading for a 100 A feederTwo standard inverse relays at 2000 A give a feeder trip at 0.23 s, an incomer trip at 0.99 s and a grading margin of 0.76 s, read off one chart.

- Đọc 6 phútAS/NZS 3008.1.1 table numbers: 2017 to 2025Each AS/NZS 3008.1.1 table AmpSize reads, with its 2017 number, its 2025 number and whether its values moved, and one submain that cites both sets.

- Đọc 4 phútAS/NZS 3008.1.1 vs 3008.1.2: AU and NZ conditionsThe AU part of AS/NZS 3008.1 rates cable at 40 °C air and the NZ part at 30 °C. One 32 A circuit needs 6 mm² in Australia and 4 mm² in New Zealand.

- Đọc 5 phútAS/NZS 3008 vs BS 7671: cable sizing comparedHow BS 7671 and AS/NZS 3000 with AS/NZS 3008.1 size a cable, where they differ, and why a BS current rating never converts into an AS/NZS one.

- Đọc 5 phútDC cable size: 48 V battery and 600 V PV arrayTwo d.c. circuits sized to AS/NZS 3008.1.1:2025, a 48 V battery-to-inverter run that current sizes and a 600 V array feed that voltage drop sizes.

- Đọc 3 phútProspective fault current at a main switchboardA 16 kA fault cleared in 0.1 s on 70 mm² copper XLPE, with the minimum conductor size, the withstand current and the k factor the adiabatic check returns.

- Đọc 5 phútAS/NZS 3008.1.1:2025: what changed from 2017The 2025 AU part adds d.c. ratings to 1500 V, renumbers every table and moves some ratings. Four circuits, each run on both editions, show what moves.

- Đọc 3 phútVoltage rise for a 5 kW solar inverter cableA 5 kW single-phase inverter 40 m from the switchboard on 10 mm² copper, with the rise in volts, the percent and the maximum length the tool returns.

- Đọc 4 phútEarth fault loop impedance and maximum ZsWhat earth fault loop impedance measures, how the maximum Zs check works, and a 32 A circuit on 6 mm² over 25 m that lands on 0.67 ohms against a 0.96 limit.

- Đọc 3 phútVoltage drop with the mV/A·m methodHow the millivolt per amp metre method works, with a 32 A run over 25 metres on 6 mm² copper and the exact drop, percent and maximum length the tool returns.

Công cụ tính mà các hướng dẫn này sử dụng
- Công cụ kiểm tra ánh sáng gây phiềnKiểm tra ánh sáng ngoài trời tại cửa sổ ở ranh giới theo AS/NZS 4282.
- Công cụ tính dòng điện máy phátDòng đầy tải và dòng sự cố của máy phát từ công suất kVA.
- Công cụ tính chớp hồ quangƯớc tính năng lượng chớp hồ quang và cấp PPE của nó.
- Chớp hồ quang và cấp ắc quyDVC, cấp nguy hiểm, năng lượng chớp hồ quang và cấp PPE của ắc quy.
- Công cụ tính phối hợp IDMTVẽ đường cong cắt của rơ le quá dòng thời gian nghịch.
- Công cụ tính khả năng chịu ngắn mạch của cápKiểm tra dây dẫn có chịu được dòng sự cố không.
- Công cụ tính cầu dao cách ly và nối đất PVĐánh giá cáp dàn PV, cầu dao cách ly d.c. và nối đất.
- Công cụ tính chuỗi PVSố tấm mỗi chuỗi, dòng chuỗi và cầu dao cách ly cho dàn PV.
- So sánh phương pháp khởi động động cơSo sánh khởi động DOL, sao-tam giác, khởi động mềm và khởi động bằng biến tần.
- Công cụ tính mạch động cơCáp, aptomat, contactor và quá tải cho một động cơ.
- Công cụ tính máy biến ápTính dòng đầy tải và tổng trở của máy biến áp.
- Công cụ tính bù hệ số công suấtTìm công suất tụ bù (kVAr) để nâng hệ số công suất.
- Công cụ tính mức ngắn mạchDòng ngắn mạch dự kiến tại một tủ điện, tính từ nguồn cấp của tủ đó.
- Công cụ tính tiết diện cápTìm tiết diện cáp nhỏ nhất đạt mọi bước kiểm tra.
- Công cụ tính tiết diện cáp DCChọn cỡ cáp d.c. đến 1500 V theo dòng điện và sụt áp.
- Công cụ tính tăng ápTính tăng áp cho phát điện phân tán hoặc PV.
- Công cụ tính tổng trở mạch vòng sự cố chạm đấtKiểm tra tổng trở mạch vòng sự cố chạm đất so với Zs tối đa.
- Công cụ tính sụt ápTính sụt áp trên tuyến cáp và kiểm tra giới hạn.