Industrial hướng dẫn
Mạch động cơ, khả năng chịu ngắn mạch và phối hợp bảo vệ cho công trình công nghiệp.
- Đọc 3 phútGenerator fault current calculation at 400 VA 500 kVA 400 V standby set at 12 % subtransient reactance gives 721.69 A full load and 6014.07 A fault current, with the decay the figure leaves out.

- Đọc 3 phútIEEE 1584-2002: arc flash model and limitsWhat the IEEE 1584-2002 empirical model governs, where it stops applying, and a 400 V switchboard study that lands on 7.54 cal/cm² at 455 mm.

- Đọc 3 phútDairy shed IDMT relay setting and gradingThree IDMT relays at a 3000 A fault, two grading margins and one curve inversion between the shed main and the farm incomer, read off the AmpSize relay engine.

- Đọc 3 phútDairy shed motor current: 15 kW at 400 VFull load current, shaft speed, torque and DOL starting current for a 15 kW 400 V dairy shed vacuum pump motor, worked through the AmpSize motor engine.

- Đọc 3 phútIEC 60255-151: IDMT curve constantsWhat IEC 60255-151 governs, which curve sets the IDMT tool carries, and a worked grading pair on standard inverse that clears in 0.21 s and 0.74 s.

- Đọc 5 phútWhat size generator for a dairy shedSize a standby set for a dairy shed from its load list. The vacuum pump's start sets the size, then staggered steps, a drive and a soft starter shrink it.

- Đọc 3 phútArc flash boundary at a motor control centreArcing current, incident energy and arc flash boundary for a 400 V MCC at 25 kA with a 0.1 s clearing time, and why the equipment type moves the result.

- Đọc 5 phútCable tray fill for a plant room: a second tierLay ten multicore cables on a 300 mm perforated tray in one layer, see when it takes a second tier, and carry the grouping factor into the cable size.

- Đọc 3 phútMotor starting current for a 55 kW DOL startFull load current, DOL starting current, shaft speed and torque for a 55 kW four pole motor at 400 V, and what a soft starter or a VSD changes.

- Đọc 2 phútIP ratings for an outdoor point and a hosed shedWhich IP code an outdoor power point, a milking shed light and a hosed switchboard need, and why an IP67 light can fail where IP65 passes.

- Đọc 3 phútStarting a loaded conveyorA 22 kW conveyor that needs 120 % torque to break away. Why star-delta and a soft starter will not start it, and what a drive or autotransformer does.

- Đọc 4 phútMotor circuit for a 15 kW pump: DOL or star-deltaSize a 15 kW 400 V pump circuit: cable, breaker, contactor and overload relay. Compare DOL, star-delta, soft starter and drive starts.

- Đọc 3 phútTransformer secondary fault current for 500 kVAA 500 kVA 11 kV to 400 V transformer at 6 percent impedance, worked through to 721.69 A of secondary full load current and 12,028.13 A of fault current.

- Đọc 3 phútFactory power factor correction: 250 kW at 0.78A 250 kW factory load at 0.78 power factor lifted to 0.95. The kvar, the capacitor steps, the current saved, the kVA released and why the bank is detuned.

- Đọc 3 phútFault level at a sub‑board, 300 kVA transformerWork the prospective fault current at a sub-board 45 m from a 300 kVA transformer, three-phase and phase-earth, and check 6 kA and 10 kA breakers against it.

- Đọc 3 phútArc flash incident energy at a 400 V switchboardA 400 V board with 20 kA bolted fault and 0.2 s clearing gives 6.23 cal/cm² at 455 mm, an arcing current of 9.64 kA and a 1395.97 mm boundary.

- Đọc 3 phútIDMT curve grading for a 100 A feederTwo standard inverse relays at 2000 A give a feeder trip at 0.23 s, an incomer trip at 0.99 s and a grading margin of 0.76 s, read off one chart.

- Đọc 4 phútAS/NZS 3008.1.2 Tables 22 to 29: deratingWhat the derating tables govern, how ambient and grouping combine into one factor, and a 63 A feeder whose capacity falls to 78.85 A on 35 mm² copper.

- Đọc 3 phútAS/NZS 3008 Table 22 (now 3.33): bunched groupingAS/NZS 3008 Table 22 is the grouping table for bunched circuits, not a temperature table. The 2025 AU part calls it Table 3.33. Read it in the calculator.

- Đọc 5 phútAS/NZS 3008 vs BS 7671: cable sizing comparedHow BS 7671 and AS/NZS 3000 with AS/NZS 3008.1 size a cable, where they differ, and why a BS current rating never converts into an AS/NZS one.

- Đọc 4 phútAWG and the NEC for NZ and AU electriciansAWG sizes and the NEC set against AS/NZS 3000 and 3008.1. A gauge converts to mm², but its rating does not, and the NEC 3 % drop figure is only a note.

- Đọc 3 phútMotor full load current: 11 kW 400 V DOLFull load current, shaft speed, torque and direct on line starting current for an 11 kW four-pole 400 V induction motor, with the figures the tool returns.

Công cụ tính mà các hướng dẫn này sử dụng
- Công cụ tính dòng điện máy phátDòng đầy tải và dòng sự cố của máy phát từ công suất kVA.
- Công cụ tính chớp hồ quangƯớc tính năng lượng chớp hồ quang và cấp PPE của nó.
- Công cụ tính phối hợp IDMTVẽ đường cong cắt của rơ le quá dòng thời gian nghịch.
- Công cụ tính động cơTìm dòng đầy tải, dòng khởi động và mômen của động cơ.
- Chọn công suất máy phát từ danh sách phụ tảiChọn cỡ máy phát từ danh sách phụ tải có khởi động động cơ.
- Độ lấp đầy máng cáp và thang cápChiều rộng máng hoặc thang cáp, số tầng, kg/m và hệ số đi chung nhóm.
- Bảng cấp bảo vệ IP và công cụ giải mãGiải mã mã IP và tìm mã IP tối thiểu cho một vị trí.
- So sánh phương pháp khởi động động cơSo sánh khởi động DOL, sao-tam giác, khởi động mềm và khởi động bằng biến tần.
- Công cụ tính mạch động cơCáp, aptomat, contactor và quá tải cho một động cơ.
- Công cụ tính máy biến ápTính dòng đầy tải và tổng trở của máy biến áp.
- Công cụ tính bù hệ số công suấtTìm công suất tụ bù (kVAr) để nâng hệ số công suất.
- Công cụ tính mức ngắn mạchDòng ngắn mạch dự kiến tại một tủ điện, tính từ nguồn cấp của tủ đó.
- Công cụ tính tiết diện cápTìm tiết diện cáp nhỏ nhất đạt mọi bước kiểm tra.
- Bộ chuyển đổi cỡ cáp hệ inch (imperial)Tìm định mức thiết bị bảo vệ cho cáp hệ inch (imperial) cũ.