Công cụ kiểm tra ánh sáng gây phiền
Kiểm tra ánh sáng ngoài trời tại cửa sổ ở ranh giới theo AS/NZS 4282.
Reads AS/NZS 4282:2023. Tables checked 1 Oct 2026.
Thử một công việc 7
Mỗi công việc điền sẵn giá trị ví dụ. Hãy thay bằng giá trị của bạn.
- Check a car-park floodlight at a boundaryWhether a 20 000 lm floodlight 15 m from an upstairs window passes after the curfew.
- Check a bollard path at a boundaryWhether a 500 lm bollard 5 m from a neighbour’s window passes in zone A3.
- Check a tennis court floodlightWhether a 40 000 lm floodlight 20 m from a window passes.
- Check a security light on a houseWhether a 2000 lm wall light 8 m from a neighbour passes.
- Check a light in a rural zoneThe limits for a 5000 lm floodlight 30 m from the boundary in dark zone A1.
- Check a loading dock before the curfewA dock floodlight against the pre-curfew limit.
- Check the upward light of an uplightThe upward light ratio of a façade uplight.
Dữ liệu nhập
Ví dụ tính toán với dữ liệu nhập mặc định.
- Vùng môi trường
- A2, Low district brightness
- Trong thời gian giới nghiêm
- Không
- Khoảng cách đến ranh giới
- 10 m
- Chiều cao tâm cửa sổ
- 1.5 m
- Bộ đèn
- 1 hàng
Độ rọi đứng tại cửa sổ
47.67lx
- Giới hạn độ rọi đứng
- 5lx
- Cường độ lớn nhất hướng về cửa sổ
- 3,143cd
- Giới hạn cường độ trên mỗi đèn
- 7,500cd
- Tỷ lệ ánh sáng hướng lên
- 0.020
- Giới hạn tỷ lệ ánh sáng hướng lên
- 0.01
Kết quả này là công cụ hỗ trợ thiết kế. Hãy kiểm tra theo tiêu chuẩn hiện hành.
Các bước tính toán
- Vùng môi trườngA2, Low district brightness
AS/NZS 4282:2023 Table 3.1
- Chu kỳNgoài giờ giới nghiêm
AS/NZS 4282:2023 Cl 3.2.4
- Hệ số bảo trì1
AS/NZS 4282:2023 Cl 3.2.2
- Tâm cửa sổ10 m out, 1.5 m up
AS/NZS 4282:2023 Cl 3.3.1.3
- Cường độ đỉnh I04,775cd
- Góc lệch so với trục chùm35.8°
- Cường độ hướng về cửa sổ3,143cd
AS/NZS 4282:2023 Cl 3.3.1.3
- Ev tại cửa sổ, 2 × 23.836 lx47.67lx
AS/NZS 4282:2023 Cl 3.3.1.3
- Độ rọi đứng tại cửa sổKết quả47.67lx
AS/NZS 4282:2023 Cl 3.3.1.3
- Giới hạn độ rọi đứng5lx
AS/NZS 4282:2023 Table 3.2
- Cường độ lớn nhất hướng về cửa sổ3,143cd
AS/NZS 4282:2023 Cl 3.3.1.3
- Giới hạn cường độ trên mỗi đèn, Level 17,500cd
AS/NZS 4282:2023 Table 3.3
- Lumen trên mặt phẳng ngang400lm
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Tổng lumen20,000lm
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Tỷ lệ ánh sáng hướng lên0.02
AS/NZS 4282:2023 Cl 3.3.1.8.2
- Giới hạn tỷ lệ ánh sáng hướng lên0.01
AS/NZS 4282:2023 Table 3.2
Giới thiệu công cụ tính này
How this is calculated
The tool estimates the light a floodlight or bollard puts on a neighbour window. It checks the result against AS/NZS 4282:2023.
- Zone and period. You pick the environmental zone, A0 to A4, and whether the curfew applies. Table 3.1 defines the zones. Cl 3.2.4 sets the curfew period.
- Intensity toward the window. The tool takes the beam angle and the tilt of each luminaire. It finds the angle off the beam axis. It then reads the intensity at that angle from a simple lobe (Cl 3.3.1.3).
- Vertical illuminance. For each luminaire, it divides the intensity by the squared distance to the window. It applies the maintenance factor of Cl 3.2.2 and adds the luminaires.
- Illuminance limit. Table 3.2 gives the vertical illuminance limit for the zone and period.
- Intensity limit. Table 3.3 gives the intensity limit for one luminaire. The tool uses the Level 1 value.
- Upward light ratio. Cl 3.3.1.8.2 gives the share of lumens above the horizontal. Table 3.2 gives the limit.
| Step | Table or clause | What it decides |
|---|---|---|
| Zone | AS/NZS 4282:2023 Table 3.1 | The environment class of the site |
| Illuminance at the window | Cl 3.3.1.3 | The vertical light on the window |
| Illuminance limit | Table 3.2 | The most light allowed at the window |
| Intensity limit | Table 3.3 | The most intensity from one luminaire |
| Upward light ratio | Cl 3.3.1.8.2 | The share of light sent above the horizontal |
Worked example
- Two floodlights at a window 10 m away. Each unit gives 10,000 lm, mounted at 6 m and tilted 30°. Zone A2 applies outside the curfew. The tool gives 47.67 lx at the window against a limit of 5 lx, so it fails. The intensity of 3,143 cd is under the limit of 7,500 cd. The upward light ratio is 0.020 against 0.01, so that check also fails.
Limits
The result is a point-source estimate. A site measurement rules. The tool uses a lobe in place of the photometric file from the maker. Use the maker intensity table when you have it. Only direct light counts. Reflected light and obstructions are not modelled.
Level 1 intensity applies. Level 2 needs a precedent from existing lighting (Cl 3.2.5). Tilting a luminaire can raise the upward fraction, so type the value at the aiming angle.
See also: Obtrusive light and the 4282 zones, Car park floodlight obtrusive light at a boundary and the lighting lumen tool.
Câu hỏi
Kết quả chỉ là công cụ hỗ trợ thiết kế. Đối chiếu với tiêu chuẩn hiện hành.
Vùng môi trường nào áp dụng cho địa điểm của tôi?
Vùng theo quy hoạch phân vùng của khu vực, kể cả quy hoạch tương lai. Hầu hết các khu ngoại ô là A3, vùng nông thôn thưa và bán nông thôn là A2, còn trung tâm thị trấn và khu công nghiệp là A4. Hãy hỏi hội đồng khi chưa rõ.
Giới nghiêm là gì?
Giới nghiêm là khoảng thời gian khuya khi áp dụng giới hạn thấp hơn. Trừ khi hội đồng hoặc giấy phép đặt giờ khác, hãy hiểu là từ 11 giờ tối đến 6 giờ sáng. Bật giới nghiêm để kiểm tra các đèn vẫn sáng qua thời gian đó.
Vì sao công cụ gọi kết quả là ước tính?
Công cụ coi mỗi hàng đèn là một điểm với chùm sáng đều. Đèn pha thực tế có bảng cường độ riêng, còn hiện trường thực tế có tường, cây và phản xạ. Để có kết quả cuối cùng, hãy dùng tính toán trắc quang hoặc đo đạc tại hiện trường.
Tỷ lệ hướng lên của bộ đèn là gì?
Tỷ lệ quang thông của đèn thoát ra phía trên phương ngang tại góc chiếu. Đèn chắn sáng hoàn toàn lắp nằm ngang có giá trị 0. Nghiêng đèn pha lên có thể làm tăng giá trị này, nên hãy lấy số liệu từ dữ liệu của nhà sản xuất tại góc nghiêng đã lắp đặt.
Giới hạn cường độ mức 1 và mức 2 là gì?
Ngoài giờ giới nghiêm, Table 3.3 đưa ra hai giới hạn cường độ. Mức 1 áp dụng cho chiếu sáng mới. Mức 2 cao hơn và cần có tiền lệ từ chiếu sáng hiện có gần đó. Công cụ kiểm tra Mức 1.
Các ví dụ tính sẵn
Nền
Các điều khoản và bảng mà công cụ này đọc
- AS/NZS 4282:2023 Cl 3.2.2Maintenance factor for obtrusive light
- AS/NZS 4282:2023 Cl 3.2.4Curfew and non‑curfew limits
- AS/NZS 4282:2023 Cl 3.2.5Level 1 and Level 2 intensity
- AS/NZS 4282:2023 Cl 3.3.1.3Illuminance and intensity at a window
- AS/NZS 4282:2023 Cl 3.3.1.8.2Upward light ratio of the system
- AS/NZS 4282:2023 Table 3.1Environmental zones
- AS/NZS 4282:2023 Table 3.2Light technical parameter limits
- AS/NZS 4282:2023 Table 3.3Maximum luminous intensities per luminaire
Mọi điều khoản và bảng, kèm cách mỗi mục đã được kiểm chứng
Các bảng được kiểm tra lần cuối ngày 1 Oct 2026.
Công cụ liên quan
- Công cụ tính tiết diện cápFind the smallest cable size that passes each check.AS/NZS 3008.1.2AS/NZS 3008.1.1AS/NZS 3000
- Công cụ tính khoảng cách đầu báo cháyDetector spacing and count for a room or corridor.NZS 4512
- Công cụ tính mạch bộ sạc xe điện (EV)Check EV chargers for spare capacity, cable size and RCD.AS/NZS 3000AS/NZS 3008.1.2AS/NZS 3008.1.1
Thông tin này có hữu ích không?